4 TOOLS CONTROL UNIT
www.jbctools.com
Page 1: ...DM 4 TOOLS CONTROL UNIT www jbctools com ...
Page 2: ...gently manage the tool temperature Work mode When the tool is used pre set work temperature is 350º C Sleep mode When the tool is in the stand the temperature goes down to 180º C depending of the configuration Hibernation mode After longer periods of inactivity pre set i e 30 minutes the power is cut off and the tool cools down to room temperature Heat management increase tip life which reduces co...
Page 3: ...s 0 4 Sleep temp 1800 C 5 Hibernationdelay 30 min 6 Temp adjust O O C Tool DR Port 1 Port 1 4 Port 1 4 Tool DR Port 1 Back Back 0 c Selected temp 350 o C P o w e r 1 0 350 Station settings 1 Temp unit Celsius 2 Maximum temp 4000 C 3 Minimum temp 2000 C 4 Nitrogenmode OFF 5 Help text OFF 6 Beep ON 7 Power limit 160W 8 Change PIN Back 3 CONTROL SCREEN SETTINGS MENU Decrease move down Increase move u...
Page 4: ... 0008871 0712 TECHNICAL SPECIFICATIONS Temperature selection from 90 C 190 F to 450 C 840 F 5 Output Peak Power 160W Safety transformer mains separator and double isolation DM 2B 230V 50 60Hz Input fuse 3 15A Output 23 5V DM 1B 120V 50 60Hz Input fuse 6A Output 23 5V DM 9B 100V 50 60Hz Input fuse 8A Output 23 5V Total weight of unit 4 4 Kg 9 7 lb Complies with CE standards on electrical safety ele...