Quick Tip Changer
1. Removing
2. Inserting
3. Fixing
Save time and change cartridges safely without switching the station off. Be careful, the cartridges
may be hot, when placing them in the storage rack.
Place the cartridge in the
extractor and pull the handle
to remove it.
Place the handle on top
of the new cartridge and
press down.
Use the holes to fix the
cartridge as follows:
A.
For curved C210
B.
For C245
C.
For straight C210
D.
cartridge Storage rack
Important:
It is essential to
insert the cartridge as far as the
mark for a proper connection.
Mark
Desoldering process
Use a tip with a larger diameter than the pad to achieve maximum aspiration and thermal efficiency.
3. Aspirating
1. Placing
2. Rotating
4. Removing
Place the tip over the
lead.
If any solder remains are left
on a terminal after desoldering it, resolder it with fresh solder and
repeat the desoldering operation.
When the solder
melts, gently move
the tip in a circular
motion.
Press and hold the
tool button to start the
suction and continue
the movement
completing 3 o 4
circles.
Remove the tip
while maintaining
the suction to make
sure all the solder is
removed from the
joint.
If desoldering tips does not provide enough heat to desolder leads from ground planes, consider
using a preheater PCB
.