WARRANTY
JBC’s 2 year warranty covers this equipment against all
manufacturing defects, including the replacement of
defective parts and labour.
Warranty does not cover product wear due to use or mis-use.
In order for the warranty to be valid, equipment must be returned,
postage paid, to the dealer where it was purchased enclosing
this form duly filled in.
www.jbctools.com
SERIAL Nº
DEALER’S STAMP
DATE OF PURCHASE
0013081-0114
TECHNICAL SPECIFICATIONS
DD
- Temperature selection from 90ºC (190ºF) to 450°C (840ºF) (±5%).
- Output Peak Power: 150W
- Safety transformer, mains separator and double isolation.
-
DD-2B
230V 50/60Hz. Input fuse: 2A. Output: 23,5V.
-
DD-1B
120V 50/60Hz. Input fuse: 4A. Output: 23,5V.
-
DD-9B
100V 50/60Hz. Input fuse: 4A. Output: 23,5V.
- Total weight of unit: 3.9Kg (8,6lb)
JT
- Temperature selection: Room temperature / 150ºC to 450°C (300ºF to 840ºF).
Cool mode: T Off, can be used to blow air at room temperature.
- Ambient Operating Temperature: 10 to 40ºC (50-104ºF)
- Output Peak Power: 1000W.
- Air flow regulation: 6-45 l/min.
- Vacuum: 30% / 228 mmHg / 9 inHg
-
JT-2B
230V 50/60Hz. Input fuse 4A.
-
JT-1B
120V 50/60Hz. Input fuse 8A.
-
JT-9B
100V 50/60Hz. Input fuse 8A.
- Total weight of unit: 5,7Kg (12,6lb)
MS-A
- Supply: 24V.
- Power: 12W.
- Weight of complete unit: 1,5 Kgs.
- Complies with CE standards on electrical safety, electromagnetic compatibility and
ESD protected housing “skin effect”.
- RoHS compliant.
- Equipotential connector and the tool tip are connected to station mains ground supply for ESD protection.
This product should not be
thrown in the garbage.