CD-S
CD-B
CA
CS
CDE-S
CDE-B
CP
OK
TOOL
EAR
THING FUSE
AUX
USE ONL
Y
WITH A 250
V FUSE
OK
º
C
º
F
A
OK
0.5s/div
Ok to reset soldering Ref.
20
16
12
8
4
355
350
345
340
335
180
Sleep
W%
ºC
Time
Energy
C245907
Ref.
2.3s
14W·s
---
---
º
C
19:29
Selected
Min 200
Max 400
350 ºC
0.5s/div
Ok to reset soldering Ref.
20
16
12
8
4
355
350
345
340
335
180
Sleep
W%
ºC
Time
Energy
C210009
Ref.
2.3s
14W·s
---
---
º
C
19:29
Selected
Min 200
Max 400
350 ºC
0.5s/div
Ok to set up soldering Ref.
20
16
12
8
4
355
350
345
340
335
350
Sel. temp. 350ºC
W%
ºC
Time
Energy
C245907
Ref.
2.3s
14W·s
---
---
º
C
19:29
0.5s/div
Ok to set up soldering Ref.
20
16
12
8
4
355
350
345
340
335
350
Sel. temp. 350ºC
W%
ºC
Time
Energy
C210009
Ref.
2.3s
14W·s
---
---
º
C
19:29
0.5s/div
Ok to reset soldering Ref.
20
16
12
8
4
355
350
345
340
335
350
Sel. temp. 350ºC
W%
ºC
Time
Energy
C245907
Ref.
2.3s
14W·s
2.4s
13W·s
º
C
95%
0.5s/div
Ok to reset soldering Ref.
20
16
12
8
4
355
350
345
340
335
350
Sel. temp. 350ºC
W%
ºC
Time
Energy
C210009
Ref.
2.2s
18W·s
2.4s
17W·s
º
C
94%
0.5s/div
Ok to reset soldering Ref.
20
16
12
8
4
355
350
345
340
335
350
Sel. temp. 350ºC
W%
ºC
Time
Energy
C245907
Ref.
2.3s
14W·s
---
---
º
C
19:29
0.5s/div
Ok to reset soldering Ref.
20
16
12
8
4
355
350
345
340
335
350
Sel. temp. 350ºC
W%
ºC
Time
Energy
C245907
Ref.
2.3s
14W·s
1.3s
8W·s
º
C
38%
19:29
19:29
19:29
0.5s/div
Ok to reset soldering Ref.
20
16
12
8
4
355
350
345
340
335
350
Sel. temp. 350ºC
W%
ºC
Time
Energy
C210009
Ref.
2.3s
14W·s
---
---
º
C
19:29
0.5s/div
Ok to reset soldering Ref.
20
16
12
8
4
355
350
345
340
335
350
Sel. temp. 350ºC
W%
ºC
Time
Energy
C210009
Ref.
2.3s
14W·s
1.3s
8W·s
º
C
38%
19:29
1s/div
150
Time
C210-008
Ref.
.
4.5s
---
º
C
SOLDERING JOINT INFO
1/3
Sel. temp.
Cartridge
Time
Max temp
Min temp
Energy
Result
Last
Ref.
Diff.
350ºC
350ºC
C245907
2.4s
350ºC
335ºC
13W·s
2.3s
C245907
-2%
350ºC
+0%
340ºC
-1%
14W·s
+29%
95%
1s/div
150
Time
C210-008
Ref.
.
4.5s
---
º
C
SOLDERING JOINT INFO
1/3
Sel. temp.
Cartridge
Time
Max temp
Min temp
Energy
Result
Last
Ref.
Diff.
350ºC
350ºC
C210009
2.4s
350ºC
335ºC
13W·s
2.3s
C210009
-2%
350ºC
+0%
340ºC
-1%
14W·s
+29%
95%
Hibernation
Tool in the stand
Actual Temp: 140ºC
25%
75%
Power
C245907
50%
19:29
325
º
C
Sel. temp.
325ºC
25%
75%
Power
C245907
50%
Sleep
Tool in the stand
Actual Temp: 290ºC
Delay to hibernation: 9:43
25%
75%
Power
C245907
50%
19:29
19:29
Hibernation
Tool in the stand
Actual Temp: 140ºC
25%
75%
Power
C210009
50%
19:29
325
º
C
Sel. temp.
325ºC
25%
75%
Power
C210009
50%
Sleep
Tool in the stand
Actual Temp: 290ºC
Delay to hibernation: 9:43
25%
75%
Power
C210009
50%
19:29
19:29
Language
Mode
Station Settings
Tool Settings
Counters
Reset
Exit
Basic
Soldering-Assistant
Back
Mode
Back
Language
Mode
Station Settings
Tool Settings
Counters
Reset
Exit
Basic
Soldering-Assistant
Back
Mode
Back
Language
Mode
Station Settings
Tool Settings
Counters
Reset
Exit
Language
Mode
Station Settings
Tool Settings
Counters
Reset
Exit
C210009
Cartridge
Back
Language
Mode
Station Settings
Tool Settings
Counters
Reset
Exit
C245907
Cartridge
OK
Back
OK
Station Settings
Recommendations
Parameter Description
Warnings
Be careful when changing these parameters as they may reduce the tip life if not used properly.
Please follow the recommended guidelines:
Parameters
Minimum Temperature
Set the minimum temperature
to work with.
Min. temp. by default is 200ºC
(392ºF). This is considered to
be a proper starting point for
leaded applications.
Maximum Temperature
Set the maximum
temperature to work with.
Max. temp by default is 400°C
(750°F). This is co
nsidered
high enough to work with
most lead-free applic
ations.
The station temperature
range is 90-450ºC
(190-840ºF). Change the
temperature limits when
working with less common
applications such as low / high
melting point soldering (HMP)
or plastics (e. g. riveting).
In most cases,
working with temperatures
over 400°C (750°F) can
damage the PCB and its
components. Even in short
time periods of tip contact
with the soldering joint, the
flux may not work properly
and could seriously reduce
tip life. If the solder joint
requires more power
(e.g. multilayered or high
dissipation boards), JBC
strongly recommends to
use preheaters.
Program Version
Shows the program version
number.
The menu gives acces to the following menu entries:
Menu Settings
Select station language
Reset to default parameters
Shows a register of solder joint values,
use for more information
See table page 15
See table below
Choose between “Basic” and “Soldering Assistant”
Return to main menu
PIN
Change the default security
PIN number (0105).
The PIN must be entered every
time a parameter is changed.
Sound
Enable/disable the beep
sound of the keypad.
Warnings
Tool Settings
Recommendations
Parameter Description
When the user changes
the cartridge type, the
parameter should be reset
to 0°C/F or to the value
needed for this cartridge.
E.g. If a correction of
+20°C (+36°F) is set for the
C245966 (thick type) and
then the user changes the
cartridge for a C245030
(which is thinner) without
resetting, they would be
working at a temperature
of +20°C (+36°F) lower for
the C245030 which does
not need any temperature
adjustment.
Temp Adjust
It provides a more precise
adjustment between the
selected temperature and the
current one.
Set values within ±50°C
(± 90°F) to achieve zero
deviation. JBC strongly
recommends the use of TID-A
or TIA-A Thermometers to
obtain precise readings.
Cartridge
Select the cartridge.
Station Settings
Recommendations
Parameter Description
Warnings
Temp Units
Celsius (ºC) or Fahrenheit (ºF)
Date & Time
Set the Date and the Time.
15
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm
130 mm
para manuales - color gris
200 mm
300 mm