Model references: CD, CF, CA, CP, CS, CV, DM, DD, DDR, NA, HD, HDR, DI, WS
Error num.
Displayed message
Solution
1
WARNING #1
Port X/Y
Shortcircuit. Check the tool.
Replace the cartridge and/or the tool.
2
WARNING #2
Port X/Y
Open circuit. Check the tool.
3
WARNING #3
No accepted tool.
Replace the tool.
Make sure it is compatible with the station.
4
WARNING #4
Port X/Y
Tool detection error. Check the tool.
6
in HD station
STOP #6
Port X/Y
Due to overload wait for unit to cool.
Unit is overheated.
Switch off and wait to cool down before new operation.
6
in other
stations
STOP #6
Port X/Y
Due to overload wait for unit to cool, JBC
recommends HD station to get more power.
Unit is overheated.
Switch off and wait to cool down before new operation.
JBC recommends to use HD station for these high power requirements.
7
in HD station
WARNING #7
Port 1/1
Shortcircuit. Check the tool.
Reset station and try new cartridge or tool.
Make sure they are compatible with the HD station.
10
in HD station
WARNING #10
Current use overloading unit. Continued use
will cause system to stop.
Unit is overheated
Switch off and wait to cool down before new operation.
STOP #10
Due to overload wait for unit to cool.
10
in other
stations
WARNING #10
Current use overloading unit. Continued use
will cause system to stop.
Unit is overheated
Switch off and wait to cool down before new operation.
Consider working with a more powerful equipment as HDE Heavy Duty station.
STOP #10
Due to overload wait for unit to cool, JBC
recommends HD station to get more power.
11
STOP #11
Error sensor temperature transformer.
Contact with the technical service.
Restart the station.
12
STOP #12
Memory error. Contact with the technical
service.
13
STOP #13
Mains frequency error. Contact with the
technical service.
Make sure the station is connected to a 50/60 Hz power source without
interference and restart the station.
If problem not solved, contact us:
0024484
-
05
22