Hibernation Delay
Set the time the tool will
remain at Sleep temperature
before entering the Hibernation
mode. At this time, the power
supply is cut off and the tip
remains at room temperature.
Tool Settings
Recommendations
Parameter Description
Warnings
Increasing the default
value will accelerate
oxidation and shorten the
tip life.
When the user changes
the cartridge type, the
parameter should be reset
to 0°C/F or to the value
needed for this cartridge.
E.g. If a correction of +20°C
(+36°F) is set for a thick
cartridge and then the
user changes to a thinner
one whitout resetting the
temperature adjustment, he
would be working at a higer
temperature than needed
for this thinner cartridge,
which does not need any
temperature adjustment.
This function completely
protects the tip from oxidation
during long periods of
inactivity while the tool is in the
stand.
Retinning the tip before
placing the tool in the stand
also helps prevent oxidation
and extends the life of the tip.
Temp Adjustment
It provides a more precise
adjustment between the
selected temperature and the
actual one.
Set values within ±50°C
(± 90°F) to achieve zero error.
JBC strongly recommends
the use of TID-A or TIA-A
Thermometers to obtain
precise readings.
12
Summary of Contents for CA-1QF 1
Page 1: ...Compact Micro Tweezers Station Ref CP QF INSTRUCTION MANUAL www jbctools com ...
Page 16: ...Notes 16 ...
Page 17: ...Notes www jbctools com 17 ...
Page 18: ...Notes 18 ...