Specifications
ALE
Automatic-Feed Soldering Control Unit
With
Solder Wire Perforation
for wire
ø
0.8mm:
Ref.
ALE-908UVA
- 100V 50/60Hz. Input fuse: T2A. Earthing Fuse: F 1.25A. Output: 23.5V
Ref.
ALE-108UVA
-
120V 50/60Hz. Input fuse: T2A. Earthing Fuse: F 1.25A. Output: 23.5V
Ref.
ALE-208UVA
- 230V 50/60Hz. Input fuse: T1A. Earthing Fuse: F 1.25A. Output: 23.5V
for wire
ø
1.0mm:
Ref.
ALE-910UVA
- 100V 50/60Hz. Input fuse: T2A. Earthing Fuse: F 1.25A. Output: 23.5V
Ref.
ALE-110UVA
-
120V 50/60Hz. Input fuse: T2A. Earthing Fuse: F 1.25A. Output: 23.5V
Ref.
ALE-210UVA
- 230V 50/60Hz. Input fuse: T1A. Earthing Fuse: F 1.25A. Output: 23.5V
for wire
ø
1.2mm.
Ref.
ALE-212UVA
- 230V 50/60Hz. Input fuse: T1A. Earthing Fuse: F 1.25A. Output: 23.5V
for wire
ø
1.6mm:
Ref.
ALE-216UVA
- 230V 50/60Hz. Input fuse: T1A. Earthing Fuse: F 1.25A. Output: 23.5V
Without
Solder Wire Perforation
for wire
ø
0.4mm:
Ref.
ALE-204UA
- 230V 50/60Hz. Input fuse: T1A. Earthing Fuse: F 1.25A. Output: 23.5V
for wire
ø
0.5mm:
Ref.
ALE-205UA
- 230V 50/60Hz. Input fuse: T1A. Earthing Fuse: F 1.25A. Output: 23.5V
for wire
ø
0.8mm:
Ref.
ALE-208UA
- 230V 50/60Hz. Input fuse: T1A. Earthing Fuse: F 1.25A. Output: 23.5V
for wire
ø
1.0mm:
Ref.
ALE-110UA
-
120V 50/60Hz. Input fuse: T2A. Earthing Fuse: F 1.25A. Output: 23.5V
- Output Peak Power:
130
W / 23.5 V
- Selectabe Temperature Range:
90 - 450 °C / 190 - 840 °F
- Idle Temp. Stability (still air):
±1.5ºC / ±3ºF (Meets and exceed IPC J-STD-001)
- Temp. Accuracy:
±3% (Using reference cartridge)
- Temp. Adjustment:
±50ºC / ±90ºF (Through station menu settings)
- Connections:
USB-A Uptade and files import-export
USB-B Software PC
RJ12 Fume extractor connection
- Equipontencial bonding:
Optional connection to EPA
- Tip to Ground Voltage/Resistance: <2 mV RMS / <2 ohms
Meets and exceed
ANSI/ESD S20.20-2014 / IPC J-STD-001F
- Ambient Operating Temp:
10 - 50 ºC / 50 - 122 ºF
18