CHANGING THE HANDPIECE’S CARTRIDGE 

C250 CARTRIDGE RANGE

-

 

Loosen the cartridge screw (

1

) to release the cartridge.

-

 

Place the cartridge in the solder feed handle.

    

Important:

 It is essential to insert the cartridge till the end for a good connection. Use the mark

    as reference.
- Align the tip of the cartridge with the solder guide tube (

3

). Tighten the cartridge screw (

1

).

- You must leave a gap of 8-10 mm between cartridge tip and the end of the guide tube (

2

). Loosen the 

guide screw (

4

). Adjust the guide tube and tighten screw (

4

).

WARNING: 

It is esential to tighten this screw for the tool to function.

All the cartridges shown are actual size.