1
3
4
2
ø 0,4
ø 0,6
1,8x0,8
ø 0,8
4,8x1,5
1,2x0,7
3,2x1,5
ø 2,2
2,2 x 1
1,2x0,7
2,2x1
4,8x1,5
ø 2,2
ø 3,8
2,2x1
ø 1,7
ø 1
www.jbctools.com
8-10 mm
12
13
1.
Loosen the cartridge screw to release it.
Place the new cartridge in the Auto-feed iron.
Alignment
Guide tube
Ref . 0002401 - Ø 0,9 - 1,1 mm
Changing cartridge
For a safe cartridge change, unplug the tool or turn the station off before following these guidelines:
2.
Align the tip of the cartridge with the
solder Guide tube.
Important:
It is essential to insert the
cartridge till the end for a good connection.
Use the mark as reference. Tighten the
cartridge screw.
3.
You must leave
a gap of 8-10
mm
between the tip and the end of the Guide
tube.
4.
Loosen the guide screw.
Adjust the Guide tube and tighten
the screw.
Adjustable Stand
Adjust the tool holder angle to suit your work position.
The AL250-B Auto-feed Iron works with C250 cartridge range. Find the model that best suits your
soldering needs in
www.jbctools.com
Compatible Cartridges
C250-420
C250-401
C250-405
C250-402
C250-406
C250-403
C250-412
C250-404
C250-418
C250-409
C250-410
C250-413
C250-407
C250-408
C250-411
C250-414
C250-415
Note: All the cartridges shown are actual size.