background image

DNS (T210N/T245N/T470N)

HDS (T470)

DNS (T210N/T245N/T470N)

HDS (T470)

DNS (T210N/T245N/T470N)

HDS (T470)

DNS (T210N/T245N/T470N)

HDS (T470)

DNS (T210N/T245N/T470N)

HDS (T470)

Quick Tip Changer

1. Removing

2. Inserting

3. Fixing

 

for ADS and DNS

Place the cartridge in the 
extractor and pull the handle 
to remove it.

Place the handle on top 
of the new cartridge and 
press the handle down.

Use the holes to fix the 
cartridge as follows:

A. 

For curved C210

B. 

For C245

C. 

For straight C210

D. 

cartridge Storage rack 

B

C

A

D

Save time and change cartridges safely without switching the station off. Be careful, the cartridges 
may be hot, when placing them in the storage rack. 

Ref. AD-SF

Ref. HD-SF

Loosen the handle screw. 
Place the Soldering Iron with 
the cartridge in the extractor  
and pull the handle to remove 
it.

Place the handle on top of the 
new cartridge and press the 
handle down.

1. Removing

2. Inserting

Handle Screw

Note: 

It is essential to insert the cartridge as far as the mark for 

a proper connection.

Mark

Note: 

For T470 handles after 

propper cartridge insertion as 
far as the mark   ,  tighten the 
handle screw.
 

Handle Screw

3. Fixing

Mark

www.jbctools.com

5

Summary of Contents for ADS

Page 1: ...ADS HDS DNS Stands for Handles INSTRUCTION MANUAL...

Page 2: ...10N T245N T470N Nitrogen Handles 1unit This manual corresponds to the following references AD SF for T210 T245 Handles HD SF for T470 Heavy Duty Handles DN SF for T210N T245N T470N Nitrogen Handles Pa...

Page 3: ...ns To Tool To Control Unit DIU DDU or DMU Wiper for Modular Tool Stand Ref CL7899 Adjustable Cable Collector Ref CC1001 Quick Tip Changer Cartridge Storage Ajustable Tool Holder Brass Wool inside Spon...

Page 4: ...r offers different ways to clean the cartridge tips If desired use the included sponge Insert the cable into the cable collector clip Do not leave the cable longer than necessary to reach the work are...

Page 5: ...witching the station off Be careful the cartridges may be hot when placing them in the storage rack Ref AD SF Ref HD SF Loosen the handle screw Place the Soldering Iron with the cartridge in the extra...

Page 6: ...tip wear The integrated wiper offers different ways to clean the cartridge tips Nozzle Extraction The quick tip changer area of DNS stand features both one slot for cartridge exchange and one for noz...

Page 7: ...n easily be removed for cleaning or replacement when they are worn Remove the wiper by pulling it out Replace the brass wool with a new one when it is worn out Place the wiper back o replace them if d...

Page 8: ...se Handle T245 General Purpose Handle T245G General Purpose Handle with Reinforced Cable T245P Blue Grip General Purpose Handle T245N Nitrogen General Purpose Handle T470 Heavy Duty Handle 1 5m 4 9ft...

Page 9: ...n be used only when cleaning the metal parts Check periodically that the metal parts of the tool stand are clean so that the station can check the tool s status Periodically check all cables and tube...

Page 10: ...ritation Be careful with the fumes produced when soldering Keep your workplace clean and tidy Wear appropriate protection glasses and gloves when working to avoid personal harm Utmost care must be tak...

Page 11: ...f HD SF Includes Sleep Mode Total Net Weight 1514 g 3 34 lb Package Dimensions Weight 342 x 155 x 120 mm 2076 g L x W x H 13 46 x 6 10 x 4 72 in 4 58 lb DNS Stand for T210N T245N T470N Nitrogen Handle...

Page 12: ...ranty covers this equipment against all manufacturing defects including the replacement of defective parts and labour Warranty does not cover product wear or misuse In order for the warranty to be val...