SPECIFICATIONS

Product Specifications and Sensitivity

Test Specifications

LD-3000 QUEST

Description

Leak detector, refrigerant gas

Sensor life

> 10 years

Response time

Instantaneous

Power supply

4 AA Alkaline batteries

Battery life

4-6 hours continuous

Warm up time

< 20 seconds

Probe length

17 inches

Weight

1 .5 lbs

Warranty

2 years (includes sensor)

SENSITIVITY

R1234yf

 .0125 oz/yr

R22

 .025 oz/yr

R32

 .05 oz/yr

R134a

 .05 oz/yr

R404A

 .05 oz/yr

R407A

 .05 oz/yr

R410A

 .05 oz/yr

R427A

 .05 oz/yr

EN14624-2012 TEST SPECIFICATIONS

Minimum/maximum  

sensitivity threshold (fixed)

1 gm/yr minimum,  

>50 gm/yr maximum

Minimum/maximum  

sensitivity threshold (moving)

3 gm/yr minimum,  

> 50 gm/yr maximum

Minimum detection time  

(1gm/yr)

Approx 1 sec

Clearing time

Approx 9 seconds after exposure 

to >50 gm/yr

Minimum threshold  

after maximum exposure

1 gm/yr

Sensitivity threshold in  

polluted atmosphere

1 gm/yr

Calibration frequency

1/yr check with calibrated  

leak standard

Summary of Contents for QUEST LD-3000

Page 1: ...T LD 3000 REFRIGERANT GAS LEAK DETECTOR OPERATINGMANUAL DetectsallHFO HFC HCFC CFC HCandPFCRefrigerants includingblends DesigncertifiedbyACSIand IntertektomeetSAEJ2791 ASCIJ2913 EN14624 2012 ASHRAE173 2012 ...

Page 2: ...atures a long life solid electrolyte sensor technology that is designed to detect difficult HFC refrigerants such as R134a R410A R404A R407A and R507 in addition to the new HFO R1234yf and all HCFC R22 and CFC R12 refrigerants including SNAP approved hydrocarbon blends The LD 3000 does not require rechargeable batteries Features Long life stable sensor Automatic calibration and reset to ambient le...

Page 3: ...ency and the probe LED begins to blink steadily 4 SEARCHING When searching for leaks move the sensor tip along A C lines and fittings no further away than 37 in 9 5 mm and no faster than 3 in sec 75 mm sec If the detector alarms make smaller sweeps back and forth until the leak source can be pinpointed NOTE The LD 3000 only responds to changes in leak concentration The alarm will reset automatical...

Page 4: ...S button once for HI sensitivity red LED will turn on and again for LO sensitivity yellow LED will turn on LeakTestVial Leak detector comes with a Leak Test Vial that allows the user to make sure the detector is operating properly To test 1 Remove the colored label dot in the center of the screw cap to expose the vent hole in the top of the cap Figure B 2 Turn on the leak detector and allow the in...

Page 5: ... the Keyway Notch in Sensor Cover with the Raised Keyway on Sensor Socket Figure D Note Do not force Sensor Cover into Socket misalignment will damage sensor pins Figure D IMPORTANT The instrument s software is designed to alert the user if the sensor is dislodged or defective If the sensor is not fully inserted into the six pin socket or if it is defective the instrument will not come out of warm...

Page 6: ...includes sensor SENSITIVITY R1234yf 0125 oz yr R22 025 oz yr R32 05 oz yr R134a 05 oz yr R404A 05 oz yr R407A 05 oz yr R410A 05 oz yr R427A 05 oz yr EN14624 2012 TEST SPECIFICATIONS Minimum maximum sensitivity threshold fixed 1 gm yr minimum 50 gm yr maximum Minimum maximum sensitivity threshold moving 3 gm yr minimum 50 gm yr maximum Minimum detection time 1gm yr Approx 1 sec Clearing time Approx...

Page 7: ... 160 F Gunk liquid wrench Ford silicone lubricant Ford pumice lotion with solvent Ford Motorcraft brake fluid Ford carburetor cleaner Dexron transmission fluid heated to 160 F Quaker State motor oil heated to 160 F Rain X is a registered trademark of ITW Global Brands Ford and Motorcraft are registered trademarks of Ford Motor Company Quaker State is a registered trademark of Quaker State Loctite ...

Page 8: ...number if applicable ReturnforRepair Products should be returned freight prepaid to JB Industries RGA _________ 601 N Farnsworth Avenue Aurora Illinois 60505 USA Contact Customer Service for RGA number 800 323 0811 Toll 630 851 9444 Tel 800 552 5593 Toll Fax 630 851 9448 Fax Warranty The LD 3000 Refrigerant Gas Leak Detector is warrantied to be free of defects in materials and workmanship for a pe...