OPERATION 

MANUAL 

 

 
JB SYSTEMS® 

3/20 

CA-16 CONTROLLER 

FUNCTIONS

 (FRONT) 

 

 

 

1. CHANNEL BUTTON: 

There are 16 channel buttons, each button has the same 

function for the corresponding channel.  

 

Just press the button once to switch on the corresponding output channel from 
the connected DMX switch pack.  

 

Press the button again to switch off the corresponding output channel of the 
connected DMX switch pack. 

2. CHANNEL INDICATOR: 

Shows the output state of the corresponding channel:

 

 

Indicator is ON: channel output is switched on. 

 

Indicator is OFF: channel output is off. 

 
 

FUNCTIONS

 (REAR) 

 

 

 

3. DMX OUTPUT: 

used to connect one or more standard DMX switch packs. Please 

use good quality DMX cable to make the connections.  

4. DC INPUT: 

connect the supplied AC/DC adapter to this input. If you should use 

another adapter, please make sure that it has 9Vdc and minimum 800mA with + in 
the center.  

5. POWER SWITCH:

 Used to switch the unit ON/OFF 

6.  AC/DC Power adapter: 

AC 230V, 50Hz 

Æ

 9Vdc / 800mA  

ENGLISH  

OPERATION 

MANUAL 

 

 
JB SYSTEMS® 

4/20 

CA-16 CONTROLLER 

CONNECTIONS 

You can connect any number of DMX switch packs to the DMX output of the CA-16. 
However the DMX-signals from the CA-16 controller use fixed addresses from 001 to 
016. So if you use 4 switch packs with each 4 channels, you will have to use the 
following start addresses on these switch packs: 001, 005, 009, 013. 
Note that if you need more than 16 channels, you will have to use a second CA-16 
controller with a separate DMX-signal cable.  
 

Example of a setup with CA-16 and four SW-416 switch packs: 

 

 

 
 
 

SPECIFICATIONS 

Power Input: 

DC 9V 800mA minimum. 

AC/DC Power adapter:

 

AC 230V, 50Hz 

Æ

 9Vdc / 800mA (or more) 

DMX outputs: 

3pin XLR  

Size:

 

482 x 63 x 44cm (19

 / 1U) 

Weight:

 1.0kg 

 

Every information is subject to change without prior notice

Summary of Contents for CA-16

Page 1: ...5 by BEGLEC cva Reproduction or publication of the content in any manner without express permission of the publisher is prohibited Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung...

Page 2: ...r transport Condense sometimes prevents the unit from working at full performance or may even cause damages This unit is for indoor use only Don t place metal objects or spill liquid inside the unit E...

Page 3: ...uld use another adapter please make sure that it has 9Vdc and minimum 800mA with in the center 5 POWER SWITCH Used to switch the unit ON OFF 6 AC DC Power adapter AC 230V 50Hz 9Vdc 800mA ENGLISH OPERA...

Page 4: ...iquement Ne pas ins rer d objet m tallique ou verser un liquide dans l appareil Risque de choc lectrique ou de dysfonctionnement Si un corps tranger est introduit dans l unit d connectez imm diatement...

Page 5: ...z utiliser un autre adaptateur assurez vous qu il produit 9Vdc et au moins 800mA avec le pole au centre 5 INTERRUPTEUR POWER est utilis pour allumer teindre l appareil 6 Adaptateur AC DC AC 230V 50Hz...

Page 6: ...nnen wanneer het na het transport naar een warm vertrek is overgebracht Condensatie kan het toestel soms verhinderen perfect te functioneren Het kan soms zelfs schade aan het apparaat toebrengen Gebru...

Page 7: ...s er dan zeker van dat hij 9Vdc en minstens 800mA produceert met de pool in het midden 5 POWER SCHAKELAAR wordt gebruikt om het toestel aan uit te schakelen 6 AC DC Power adapter AC 230V 50Hz 9Vdc 800...

Page 8: ...idung von Stromschlag oder Feuer Ger t bitte nicht Regen oder Feuchtigkeit aussetzen Zur Vermeidung von Kondensation im Inneren des Ger ts bitte nach Transport in eine warme Umgebung einige Zeit zum T...

Page 9: ...Sie sich bitte dass dieser 9Vdc und mindestens 800mA hat 5 POWER SCHALTER Schaltet das Ger t an und aus 6 AC DC Power Adapter AC 230V 50Hz 9Vdc 800mA DEUTSCH BEDIENUNGSANLEITUNG JB SYSTEMS 16 20 CA 16...

Page 10: ...rmita que la unidad se adapte a las temperaturas circundantes cuando la lleve a una habitaci n c lida despu s de transporte Condensaci n algunas veces impide que la unidad funcione a rendimiento pleno...

Page 11: ...aptador AC DC abastecido con el aparato a esta entrada Si usted debe utilizar otro adaptador aseg rese que produce 9Vdc y por lo menos 800mA con el en el centro 5 INTERRUPTOR POWER Es utilizado para e...

Reviews: