background image

39

VARYSCAN 4 COMPACT PLUS  575 HMI

R31

30R

1W

R32

60R

0,6W

R33

240R

0,6W

R34

120R

0,6W

R35

4R

1W

R36

1R

1W

R37

1R

1W

R38

36R

1W

R39

36R

1W

R40

1R

1W

C1

18pF

C41

220nF

C2

18pF

C42

2,2nF

C3

4,7uF/35V

C43

100nF

C4

100nF

C44

470uF/35V

C5

100nF

C45

2,2nF

C6

22uF/35V

C46

47u/35V

C7

100nF

C47

220nF

C8

100nF

C48

47u/35V

C9

100nF

C49

220nF

C10

820pF

C50

4700uF/35V

C11

820pF

D1

LM336

C12

47uF/35V

D2

Bridge

C13

220nF

F1

Fuse

C14

220nF

JP1

Header 4

C15

47uF/35V

JP2

Header 4

C16

220nF

JP3

Header 4

C17

220nF

JP4

Header 4

C18

100nF

JP5

Header 4

C19

3,3nF

JP6

Header 2

C20

220nF

P1

Connector DB15

C21

47uF/35V

P2

Connector DB15

C22

220nF

Q1

BC337B

C23

47uF/35V

Q2

BC337B

C24

820pF

Q3

BC337B

C25

820pF

Q4

BC337B

C26

3,3nF

Q5

BC337B

C27

47uF/35V

Q6

BC337B

C28

220nF

Q7

BC337B

C29

220nF

Q8

BC337B

C30

220nF

Q9

BC337B

C31

47uF/35V

Q10

BC337B

C32

820pF

Q11

BC337B

C33

820pF

Q12

BC337B

C34

3,3nF

Q13

BC337B

C35

220nF

Y1

Quarz 16MHz

C36

220nF

C37

2,2nF

C38

47uF/35V

C39

220nF

C40

47uF/35V

Summary of Contents for VARYSCAN 4 COMPACT PLUS 575 HMI

Page 1: ...lighting Lichtanlagentechnik GmbH Sallersteigweg 15 D 89134 Blaustein Wippingen Telefon 49 0 7304 9617 0 Telefax 49 0 7304 9617 99 http www jb lighting de english Bedienungsanleitung User Manual Deuts...

Page 2: ...ir of defects 30 Adjustment of mirror stop 30 Adjustment of the motor brake 30 Regular Maintenance Performances 30 1 Cleaning of all Optical Parts 31 2 Cleaning of Ventilation 31 3 Oiling of Rotating...

Page 3: ...24 VARYSCAN 4 COMPACT PLUS 575 HMI Illustration of VS 4 1200HMI...

Page 4: ...on of operating sections Occupation of DMX sockets DMX in DMX out Pin No signal Colour of wire Pin No Signal Colour of wire 1 Ground black 1 Ground black 2 DMX white 2 DMX white 3 DMX red 3 DMX red 4...

Page 5: ...lder Warning Never touch the glass of bulb of the 575 HMI bulb itself An adjustment of the bulb is not necessary Mounting of Mirror Take the mirror with the metalsheet put it on the y motor and close...

Page 6: ...ging DIP switch No 2 switch 1 i e the moment this function is turned on every DMX factor between 0 and 128 corresponds to an adjustment of the colour wheel You can produce not only half colours but 1...

Page 7: ...No 2 switch 4 If you would like to reset your Varyscan from your DMX desk turn switch 4 on at DIP switch No 2 Now you have the possibility to reset your Varyscan if you transmit DMX factor 255 via gob...

Page 8: ...the four screws After opening you should unscrew the silver screws on the side of the Varyscan to put out the slides Now you are able to press the gobos at the gobo wheel out of their holder and then...

Page 9: ...tart your Varyscan Now wait until the initialisation of the scan is ran through and all motors stopped Then loosen screw No 1 Now turn the holder for the y motor towards the stop up to a distance of 0...

Page 10: ...tilation inlets and the interior of the Varyscan are free from fuzzes and other dust Open both lids of your Varyscan by screwing off the screws from the lids Now clean your Varyscan carefully with a v...

Page 11: ...5 if at DIP switch No 2 switch 4 is ON gobo 5 DMX 160 254 Reset DMX 255 channel 4 colour colour 0 white DMX 000 007 colour 1 DMX 008 015 colour 2 red DMX 016 023 colour 3 DMX 024 031 colour 4 yellow D...

Page 12: ...s Clay Paky Goldenscan 3 compatible channel 1 iris and gobo rotation channel 2 colour channel 3 gobo and effect wheel channel 4 dimmer shutter channel 5 pan movement channel 6 tilt movement channel 1...

Page 13: ...er DMX 099 107 gobo 2 prism DMX 108 116 gobo 3 white DMX 117 125 gobo 3 artificial light filter DMX 126 134 gobo 3 daylight filter DMX 135 143 gobo 3 prism DMX 144 152 gobo 4 white DMX 153 161 gobo 4...

Page 14: ...light filter DMX 126 134 gobo 3 daylight filter DMX 135 143 gobo 3 prism DMX 144 152 gobo 4 white DMX 153 161 gobo 4 artificial light filter DMX 162 170 gobo 4 daylight filter DMX 171 179 gobo 4 prism...

Page 15: ...speed DMX 222 rotation stop DMX 223 224 rotation right lowest speed DMX 225 rotation right highest speed DMX 255 Occupation DMX In DMX Out Position of sockets see page 5 DMX IN DMX OUT Pin1 ground bla...

Page 16: ...he polarity of the Eprom The inlet of the Eprom has to point to the same direction as the inlet of the IC holder Close the lid and fix it with screws Plug in your Varyscan and please test all function...

Page 17: ...e 2 red 3 black 4 gr bl JP1 List of parts for electronic board of Varyscan 4 Compact Plus 575 HMI R1 10M 0 6W R41 1R 1W R2 22K 0 6W R42 36R 1W R3 9 10K Sip 0 25W R43 36R 1W R4 9 10K Sip 0 25W R44 1R 1...

Page 18: ...35V D2 Bridge C13 220nF F1 Fuse C14 220nF JP1 Header 4 C15 47uF 35V JP2 Header 4 C16 220nF JP3 Header 4 C17 220nF JP4 Header 4 C18 100nF JP5 Header 4 C19 3 3nF JP6 Header 2 C20 220nF P1 Connector DB15...

Page 19: ...40 VARYSCAN 4 COMPACT PLUS 575 HMI Plan of electronic parts for electronic board of VS 4 Compact Plus 575 HMI...