Varyscan 3 Special 250MSD
25
JB-lighting Lichtanlagentechnik GmbH Sallersteigweg 15 D-89134 Blaustein Tel. ++49-7304-9617-0
JP1
JP2
JP3
JP4
JP5
JP6
JP7
JP8
JP9
JP10
JP11
S1
S2
Description
DMX-In
SM effect wheel
12V input
SM gobo wheel
SM colour wheel
fan output
SM gobo rotation
SM dimmer 1
SM
movement
SM tilt movement
SM dimmer 2
DMX-In
DMX-Out
pan
Pin 1
not occupied
red
brown
red
red
not occupied
red
red
red
red
red
black
black
Pin 2
black
blue
brown
blue
blue
not o.
blue
blue
blue
blue
blue
white
white
Pin 3
red
yellow
-----
yellow
yellow
black
yellow
yellow
yellow
yellow
yellow
red
red
Pin 4
white
white
-----
white
white
red
white
white
white
white
white
-----
-----
5. Troubleshooting
5.1 Change thermal fuse
5.2 Change eprom (software)
5.3 Pin assignment
Remove the circuit board cover which is located behind the mirror holder, by loosening
the screws. Compare the circuit board with the diagram on page 26 to locate the eprom.
Remove the eprom very carefully from the socket and insert the new eprom. The small
mark on the eprom and the eprom socket indicates the right position of the eprom. Make
sure both marks match. Check the pins contact.
Reassemble the cover of the circuit board and test the Varyscans functions.
WARNING: Contact qualified service personnel!
Warning: Disconnect fixture from mains, and allow
hot lamp to cool down for at least 30 minutes!
Warning: Disconnect fixture from mains, and allow
hot lamp to cool down for at least 30 minutes!
Remove the 8 screws holding the top cover of the Varyscan and remove it.
Clean the unit (see chapter 4.1).
Loosen the nut which holds the ignitor and place the ignitor outside the case without
removing the cables. The thermal fuse it located in the cable which runs from ballast
to the fuse.
Unsolder the cable from fuse and remove cable by pulling it backwards. Remove the
silicone fabric hose from the thermal fuse and unsolder it from the cable. Install the
new thermal fuse, but make sure not to overheat it during the process of soldering.
Use a continuity tester to check the continuity and coat the cable and the thermal fuse
again with the fabric hose. The fabric hose is most important, because the thermal
fuse is live.
Reassemble the Varyscan.
Test the fan to ensure it is working. A defective fan is the most common reason for
a defective thermal fuse.