MECHANICAL INSTALLATION

Selecting the location

Select a suitable location for installation of the module.
The module should be face sun, reduce loss from exterior sunshine and raise export power.
Detailed information on optimal module orientation will depend on the sunlight and specific system design.
For the optimal annual output from the solar module, we suggest the mounting angle be equal to the latitude
of the city where the modules are being installed. For the optimal battery performance in winter months, we
suggest the mounting angle be 10 degrees greater than the latitude of the city where the installation is being
done. For optimal solar battery performance in all four seasons

we suggest the mounting angle be 10

degrees less than latitude of the city where the installation is being done.
A mounting location should be chosen where the module will not be shaded at any time of the day.
Do not install the module near other equipment or in locations where flammable gases can be generated or
collected.
The fire rating of this module is valid only when mounted in the manner specified in the mechanical mounting
instructions.
Modules can not be used in other excessive and harsh environments, such as hail, snow, sand, smoke, air
pollution, soot, flammable gases, near open flames, and highly corrosive substances (salt, salt spray, salt
water, acid rain) , As this will affect the module's safety and performance. If the installation environment is
special, such as the seaside, farm, high humidity or wind and other large environment, please consult your
local dealer for professional support and confirmation. If you need to be installed at a high altitude, the
altitude should not exceed 2000m.

Selecting the Proper Mounting Structure and Hardware

1

Mounting Structure

1

Screw fitting:

Observe all instructions and safety precautions included with the mounting system to be used with the
module.
The aluminous frame has eight (8) mounting holes, and two (2) holes for grounding.
Do not drill holes in the glass surface of the module. Doing so will void the warranty.
Do not drill additional mounting holes in the module frame. Doing so will void the warranty.
Modules must be securely attached to the mounting structure (racking) using eight (8) mounting points for
normal installation. If heavy wind or snow loads are anticipated, we require advance notification. Load
calculations are the responsibility of the system designer or installer.
The support module mounting structure must be made of durable, anticorrosion and UV-resistant material.

Hardware

The size of fixing hole for common modules is 9*14 and the size of the fixing nut is M8. The size of fixing hole
for common modules is 7*12 and the size of the fixing nut is M6.Drawings as follows.

2 / 13

Summary of Contents for JY200P6-Ad-5

Page 1: ...cted in parallel the total current is equal to the sum of individual module current Keep children well away from the system while transporting and installing mechanical and electrical components Completely cover the module with an opaque material during installation to keep electricity from being generated Abide with the safety regulations for all other components used in the system including wiri...

Page 2: ...s Modules can not be used in other excessive and harsh environments such as hail snow sand smoke air pollution soot flammable gases near open flames and highly corrosive substances salt salt spray salt water acid rain As this will affect the module s safety and performance If the installation environment is special such as the seaside farm high humidity or wind and other large environment please c...

Page 3: ...odule type Cell quantity Dimensions mm A B C D E F H I 6 12 1956 992 50 942 1676 1176 M8 35 6 12 1956 992 40 949 1676 1176 M6 28 6 10 1650 992 35 40 50 942 1370 870 M8 35 6 10 1650 992 40 949 1370 870 M6 28 6 10 1640 992 35 40 50 942 1360 860 M8 35 156 Mono Poly silicon 6 10 1640 992 40 949 1360 860 M6 28 White 6 10 1636 992 35 40 50 942 1356 856 M8 35 6 10 1636 992 40 949 1356 856 M6 28 6 9 1482 ...

Page 4: ...inless steel Caution Guard against contact between different metals Doing so will give rise to electrochemical corrosion 2 Clamp fitting Use a certain number of clamps to fix the modules on the mounting rail The module clamps should not come into contact with the front glass and must not deform the frame Be sure to avoid shadowing effects from the module clamps The module frame is not to be modifi...

Page 5: ...5 11 14 0 5 2 2 5 3 JYXXXP6 Aa 5 6 12 1956 992 50 490 11 14 0 5 2 2 5 3 JYXXXP6 Ab 5 6 10 1636 992 50 427 11 14 0 5 2 2 5 3 156 Poly silicon JYXXXP6 Ab 5 6 10 1640 992 50 428 11 14 0 5 2 2 5 3 White JYXXXP6 Ab 5 6 10 1650 992 50 430 11 14 0 5 2 2 5 3 JYXXXP6 Ac 5 6 9 1482 992 50 396 11 14 0 5 2 2 5 3 JYXXXP6 Ad 5 6 8 1325 992 50 365 11 14 0 5 2 2 5 3 Table 2 Mechanical dimensions when modules inst...

Page 6: ...les as shown in figure 2 Use an end clamp to fix the edge module as shown in figure 1 Use hexagon screwdriver to tighten the clamp on the rail securely All clamps include bolts and flange nuts are stainless steel 1 end clamp 2 mid clamp 2 Mounting Methods Ground Mount Select the height of the mounting system that prevents the lowest edge of the modules from being covered by snow for an extended pe...

Page 7: ...me cases a special support frame may be necessary Module could be used in Fire safety Class C To maintain the corresponding fire prevention level the tilt angle should be no less than 5 in ft 127 mm 305 mm when the modules are mounted on the roof When installing the module on a roof or building do so in calm winds Installing a module during strong winds may cause accidents Pole mount When installi...

Page 8: ...o 1954381 2 When using grounding clips the grounding conductor should be inserted into the aluminum frame as shown above in Figure 2 and secured using the 8 32 set screw Then use a nut included with the Tyco grounding clip to secure the entire assembly as shown Next insert the 12 10 AWG solid un insulated ground wire into the slot of the lug see the picture and screw down the slotted screw Recomme...

Page 9: ...ot use dishwasher detergent Electrical and mechanical connections should be checked periodically by qualified personnel to verify that they are clean secure and undamaged Check the electrical and mechanical connections periodically to verify that they are clean secure and undamaged Problems should only be investigated by qualified personnel Observe the maintenance instructions for all other compon...

Page 10: ...ge or expense arising out of or in any way connected with such installation operation use or maintenance No responsibility is assumed by Jayu Solar for any infringement of patents or other rights of third parties which may result from use of the PV product No license is granted by implication or otherwise under any patent or patent rights The information in this manual is based on Jayu Solar s kno...

Page 11: ... Ab 5 40 22 9 33 32 98 8 93 295 00 18 13 JY290M6 Ab 5 39 90 9 30 32 64 8 87 290 00 17 83 JY285M6 Ab 5 39 86 9 21 32 57 8 75 285 00 17 52 JY280M6 Ab 5 39 56 9 09 32 42 8 62 280 00 17 21 JY275M6 Ab 5 38 89 9 04 32 20 8 55 275 00 16 90 JY270M6 Ab 5 38 72 8 89 32 02 8 42 270 00 16 60 JY265M6 Ab 5 38 45 8 79 31 56 8 40 265 00 16 29 JY270M6 Ac 5 36 43 9 62 30 26 8 94 270 00 18 37 JY265M6 Ac 5 36 22 9 45...

Page 12: ...46 96 9 07 37 92 8 57 325 16 75 JY320P6 Aa 5 46 76 9 00 37 69 8 49 320 16 49 JY315P6 Aa 5 46 37 8 89 37 44 8 41 315 16 23 JY310P6 Aa 5 46 07 8 83 37 21 8 33 310 15 98 JY305P6 Aa 5 45 77 8 77 36 96 8 25 305 15 72 JY300P6 Aa 5 45 46 8 71 36 71 8 17 300 15 46 JY295P6 Aa 5 45 27 8 62 36 46 8 09 295 15 20 JY295P6 Ab 5 40 52 9 41 32 96 8 94 295 18 13 JY290P6 Ab 5 40 31 9 32 32 86 8 82 290 17 83 JY285P6 ...

Page 13: ...36 01 9 22 28 95 8 81 255 17 35 JY250P6 Ac 5 35 71 9 10 28 79 8 68 250 17 01 JY245P6 Ac 5 35 40 9 02 28 57 8 58 245 16 67 JY240P6 Ac 5 35 10 8 95 28 27 8 50 240 16 32 JY235P6 Ac 5 34 82 8 88 28 11 8 37 235 15 98 JY240P6 Ad 5 35 10 8 95 28 27 8 49 240 18 26 JY235P6 Ad 5 34 79 8 88 28 05 8 38 235 17 88 JY230P6 Ad 5 34 49 8 80 27 78 8 28 230 17 50 JY225P6 Ad 5 34 28 8 69 27 54 8 17 225 17 12 JY220P6 ...

Reviews: