FIGURE 2
QTY
DESCRIPTION
PART #
ITEM
8
ANCHOR ROD 7/8 -9 x 18
FBGP601
9
8
LOCK NUT 7/8 -9
HN5017
10
16
STANDARD FLAT WASHER 7/8
HW5003
11
16
HEX NUT 7/8 -9
HN5020
12
2
LEVELING PLATE
FBGP602
13
EFFECTIVE DATE:
DRAWN BY:
5/31/2017
MODEL NUMBER:
CHECKED BY:
PRODUCT NAME:
Moune T.
FBGP-600
OFFICIAL 5FT OFFSET FOOTBALL
GOAL POST w/ LEVELING PLATE
WVB
PLAYING SURFACE
FBGP-600
FOOTBALL GOAL
FOOTING INSTALLATION
121"
*
62 1/4"
OFFSET FROM
CENTER OF UPRIGHT
TO INSIDE EDGE OF
END ZONE END LINE
FIELD SIDE
ASSUMES APPROXIMATELY 1"
DEFLECTION AFTER INSTALLATION
OF CROSSBAR AND UPRIGHTS
8"
60"
36"
12"
TYP
*
TYPICAL
RE-BAR
FOOTING DETAILS:
1) CHECK LOCAL BUILDING CODES BEFORE
STARTING THE FOOTING, AS BUILDING CODES
MAY VARY. LOCAL BUILDING CODES SHOULD BE
ADHERED TO IF REQUIREMENTS ARE GREATER
THAN THOSE OUTLINED HERE.
2) IT I STRONGLY RECOMMENDED THAT THE
POURED FOOTING BE REINFORCED WITH A
MINIMUM OF 6 PIECES OF 3/4" x 60" RE-BAR.
11"
REF
9
13
10
11
12
11
12
NUT PRE-INSTALLED
GOOSENECK
12" TYP
127 1/4"