background image

NOVEMBER 2016

8

 

3000

3000  

or less

more than 3000

1000 min.  

if clear 

within 3000  

of flue top

increase as necessary until 

nothing within 3000 of flue top

any nearby structure

3000

600

5

increase from 

1000 min.  

until clear  

within 3000  

of flue top

3000  

or less

more than 3000

3000

600

DIAGRAM 4

Notes:

Depending on local circumstances, taller chimneys may

be required for satisfactory performance, check with your 

local retailer or installation technician.

DIAGRAM D – AS/NZS 2918:2001

MINIMUM HEIGHTS FOR FLUE SYSTEM

WALLTHERM

®

 

AIR

Summary of Contents for WALLTHERM AIR

Page 1: ... the wood fire allows the OUTER GALV LINER to clear all structural roof timbers 2 Cut a 250mm square hole in the ceiling Directly above cut a hole in roof to accommodate OUTER GALV LINER 3 Fit a timber frame around the ceiling i e frames form a 250mm square aperture that allows air to circulate freely over the OUTER GALV LINER surface 4 Position the OUTER GALV LINER so that it is flush with the un...

Page 2: ...IPE securing with three Monel rivets at each joint 10 Check the FLUE PIPE SPACING BRACKETS inside the INNER GALV LINER are correctly positioned and then from the roof slide the INNER GALV LINER into the OUTER GALV LINER until the brackets rest on to the internal swage ring of the OUTER GALV LINER this will ensure the INNER GALV LINER is the correct 12mm above ceiling level 11 Before securing the O...

Page 3: ...ructions and the manufacturer s instructions on how to operate the appliance are met 16 Fitting the double flue shield MKIII Fasten the lower FLUE SHIELD BRACKET to the INNER FLUE SHIELD Use the Walltherm AIR specification sheet to determine the shield height above the heater when fitted to the FLUE SHIELD SPIGOT BRACKET point 7 Fasten the top FLUE SHIELD BRACKET assembly as shown When completed t...

Page 4: ... the ceiling end of the liners D Point 10 will differ from the flat ceiling installation in that the 200mm Inner Liner will need to be 6mm lower than the 250mm Outer Liner as shown in Diagram C E Ensure the 150mm 200 spider is secured to the flue pipe and is free floating inside the 200mm Inner Liner F The 200mm 250mm spider must be secured to both the 200mm Inner and 250mm Outer Liners once they ...

Page 5: ... MOVE SLIP LINER UP OR DOWN TO OBTAIN CORRECT HEIGHT FLASHING TO WEATHERPROOF AROUND LINER WHERE IT EXITS THE ROOF GALV LINER IS FIXED TO MOUNTING RAILS BY RIVETS OR SCREWS OUTER GALV LINER CAN BE SECURED DIRECTLY TO TIMBER FRAMING 4 6 METRES FROM TOP OF FLOOR PROTECTOR TO TOP OF FLUE PIPE See Diagram B for exploded view OUTER GALV LINER CAN BE SECURED DIRECTLY TO TIMBER FRAMING MOUNTING RAILS SUP...

Page 6: ...iling Timber Framing Tighten the Ceiling Plate so it touches the ceiling DO NOT OVER TIGHTEN THIS DIAGRAM IS SUITABLE FOR FLAT CEILINGS ONLY The 250mm Outer Liner can be secured directly to timber framing at both the Ceiling and Roof penetration ends POSITIONING LINERS AND CEILING PLATE DIAGRAM B WALLTHERM AIR ...

Page 7: ...250mm Outer Liner can be secured directly to timber framing at both the ceiling roof penetration ends This diagram is suitable for sloping ceilings 15 45 degrees 6 DETAIL B SCALE 1 2 The 200mm Inner Liner must extend 6mm lower than the 250mm Outer Liner to ensure the correct air flow DIAGRAM C POSITIONING LINERS AND CEILING PLATE WALLTHERM AIR ...

Page 8: ...by structure 3000 600 5 increase from 1000 min until clear within 3000 of flue top 3000 or less more than 3000 3000 600 DIAGRAM 4 Notes Depending on local circumstances taller chimneys may be required for satisfactory performance check with your local retailer or installation technician DIAGRAM D AS NZS 2918 2001 MINIMUM HEIGHTS FOR FLUE SYSTEM WALLTHERM AIR ...

Page 9: ...NOVEMBER 2016 9 392 892 4 11 11 170 240 Hole cut for 45 degree ceiling Ceiling Plate required as tested 9 DIAGRAM OF 45 CEILING PLATE WALLTHERM AIR ...

Page 10: ...0 250mm 1 x Ceiling Plate 150mm Black 370mm Square 1 x Ceiling Plate Screw Pack 4 1 x Top Spacing Bracket Bolt and Nut 2 x 40 x 40 x 1200mm Galvanised Mounting Rails 1 x Double Flue Shield MKIII 1 x Top Flue Shield Bracket Part A B 1 x Bottom Flue Shield Bracket Multi fit OPTIONAL COMPONENTS FOR A SLOPING CEILING NOT SUPPLIED IN KIT 1X polished SS ceiling plate at 45 30 or 15 1X white ceiling plat...

Page 11: ...NOVEMBER 2016 11 ...

Reviews: