Section 8: Plumbing System
118
heating the water because of incomplete combustion of the burner at these higher altitudes.
Consult with the local propane company, your dealer or the water heater manufacturer for
proper derating of the water heater. Change out of the orifice (derating) should be done by
the dealer or a qualified service agency.
Pressure and Temperature Relief Valve
The temperature and pressure relief valve is designed to open if the temperature of the water
within the heater reaches 120° F, or if the water pressure in the heater reaches 150 pounds.
When this pressure is reached, the pressure relief valve will open and water will drip from
the valve.
This “weeping” or dripping will continue until the pressure is reduced to below 150 pounds,
and the valve closes. This condition is normal and does not indicate a defective relief valve.
One way to reduce the frequency of this occurrence is to maintain an air pocket at the top
of the water heater tank. This air pocket will form in the tank by design; however, it will be
reduced over time by the everyday use of your water heater. To replenish this air pocket:
1.
Turn off the water heater.
2.
Turn off the cold water supply line.
3.
Open a faucet in the recreation vehicle.
4.
Pull out the handle of the pressure relief (P&T) valve and allow water to flow from the
valve until it stops.
5.
Release the handle on the P&T valve - it should snap closed.
Close the faucet and turn on the cold water supply. As the tank fills, the air pocket will de
-
velop. Repeat this procedure as often as needed to reduce the frequency of the weeping P&T
valve.
Maintenance
Do not allow the burner to burn with a yellow flame, or continue to operate the water heater
with an improper burner flame.
Periodically, inspect the water heater vent for soot. Soot is a sign of incomplete combustion
and must be corrected before operating the water heater. This is your visual warning that the
water heater is operating in an unsafe manner. If soot is present, immediately shut the unit
down and contact your dealer or a qualified service agency.
Periodically inspect the vent for obstructions. Do not terminate the vent on your water
heater inside of add-on rooms, screen porches or patios. Doing so will result in products of
combustion being vented into the rooms or occupied areas.
Do not place a valve between the pressure and temperature (P&T) valve and
the tank. Do not remove or plug the relief valve under any circumstances.
NOTE:
It is important that once the RV has returned to lower
elevation (below 4500 feet) any high altitude deration or other adjust
-
ments be reversed for proper operation of the water heater.
Table of Contents
Maintenance Record
Summary of Contents for Hummingbird Towables 2019
Page 1: ...Owner s Manual PRINTED ON RECYCLED PAPER 0283457 2019 2019 Towables...
Page 2: ......
Page 4: ......
Page 12: ...10 Table of Contents Maintenance Record...
Page 25: ...Section 1 Warranty Service 23 Table of Contents Maintenance Record...
Page 26: ...Section 1 Warranty Service 24 Notes Table of Contents Maintenance Record...
Page 44: ...Section 3 Pre Travel Information 42 Notes Table of Contents Maintenance Record...
Page 64: ...Section 4 Vehicle Operation 62 Table of Contents Maintenance Record...
Page 94: ...Section 6 Electrical System 92 Table of Contents Maintenance Record...
Page 104: ...Section 7 Fuel Propane System 102 Notes Table of Contents Maintenance Record...
Page 140: ...Section 11 Electronics 138 Notes Table of Contents Maintenance Record...
Page 155: ...Section 13 Exterior 153 Travel Trailers Sealant Diagram Table of Contents Maintenance Record...
Page 156: ...Section 13 Exterior 154 Notes Table of Contents Maintenance Record...
Page 160: ...Section 14 Travel Camping Storage Checklists 158 Notes Table of Contents Maintenance Record...
Page 165: ...Section 15 Additional Information 163 Notes Table of Contents Maintenance Record...