Section 6: Electrical System
86
Rotating Dial Disconnect Switch
When this switch is ON, there will be a green area showing a
“1” along the top of the switch. To turn the switch OFF, turn it
counter-clockwise until you see the red area along the left side of
the switch showing a “0” (zero).
Lever Type Disconnect Switch
To operate this switch, turn the lever counter-clockwise to turn
off all 12VDC power to the fuse panel in the RV. The lever can
be removed and is equipped with a lanyard to keep the key from
getting lost.
Battery Disconnect Switches
Switch appearance may vary
by model
Load Center
The Load Center contains
12VDC fuses and 120VAC
circuit breakers for almost all
of the electrical appliances
and circuits in the RV. The
120V main breaker may be
located in this panel and will
turn off all 120-volt power
to the RV. Locations will
vary by model. Refer to the
diagram inside the load center
for specific fuse assignments.
Not all load centers will include a main breaker.
Motor homes may have separate small panels for breakers and fuses. They are normally
located in close proximity to each other typically in the bed platform. The converter is also
mounted separately (typically under the bed platform).
Typical Load Center Panel
Load Center Panel w/120 volt Main breaker
– load center appearance and configuration
may vary by model
120-Volt Circuit Breakers
The 120-volt AC circuit breakers located inside the load center protect all 120-volt wiring
and components from circuit overloads and short circuits. Should a circuit overload or short
circuit occur the circuit breaker protecting the affected circuit will “trip” preventing the flow
of electricity through that circuit.
If a circuit breaker trips, shut “off” the appliance on that circuit (i.e., power converter etc.)
and allow the circuit breaker to cool down for a brief period of time. After it cools down,
reset the circuit breaker by moving its lever “off” and then back to the “on” position. If the
circuit breaker re-trips or frequently trips, contact your dealer to have the electrical problem
diagnosed and repaired.
A circuit breaker identification label is permanently attached to the inside surface of the
120-volt Load Center.
Table of Contents
Maintenance Record
Summary of Contents for Hummingbird 2018
Page 1: ...Owner sManual PRINTED ON RECYCLED PAPER 0283457 2018 2018 Towables...
Page 2: ......
Page 4: ......
Page 10: ......
Page 12: ...8 Table of Contents Maintenance Record...
Page 28: ...Section 1 Warranty Service 24 Notes Table of Contents Maintenance Record...
Page 46: ...Section 3 Pre Travel Information 42 Notes Table of Contents Maintenance Record...
Page 64: ...Section 4 Vehicle Operation 60 Notes Table of Contents Maintenance Record...
Page 136: ...Section 10 Appliances 132 Notes Table of Contents Maintenance Record...
Page 138: ...Section 11 Electronics 134 Notes Table of Contents Maintenance Record...
Page 149: ...Section 13 Exterior 145 Travel Trailers Sealant Diagram Table of Contents Maintenance Record...
Page 150: ...Section 13 Exterior 146 Notes Table of Contents Maintenance Record...
Page 154: ...Section 14 Travel Camping Storage Checklists 150 Notes Table of Contents Maintenance Record...
Page 159: ...Section 15 Additional Information 155 Notes Table of Contents Maintenance Record...