Section 8: Plumbing System
131
12. Set the valves to the
DRY CAMPING
setting.
Green valve points down
Blue valve points to the right
Water Heater Bypass valve is still set to
BYPASS
.
13.
Turn the water pump ON and sanitized water will flow into the water
lines from the water tank (when a fixture is opened).
14.
Open hot water faucets one by one until water begins to flow continuously and a chlo
-
rine smell is noticeable. Close hot water faucets. Repeat this process with the cold
water faucets. Include outside shower faucets (if so equipped) and outside kitchen
faucets as well (if equipped).
15. Turn OFF the water pump.
16. Let the solution remain in the tank and lines for at least four hours when disinfecting
with 50-PPM residual chlorine. If a shorter time period is desired, then a 100-PPM
chlorine concentration should be permitted to sit in the system for at least one hour.
17. After the required period, drain the chlorine solution from the fresh water system.
Rinse the system with fresh water:
1.
Fill the fresh water tank full of clean (potable) water. Use water either from a pressur-
ized source, or from a container (as detailed below).
a).
Filling from a pressurized source:
Attach your fresh water
hose to the CITY WATER CONNECTION inlet at the utility
center. Connect the other end of the hose to a pressurized
water source. Colored valves should be in the TANK FILL
position. Turn the water on and finish filling the water tank
with fresh water.
DO NOT OVERFILL THE TANK!
Use
the LED indicators on the tank monitor inside the RV at the Command Center
panel to monitor water level in fresh water tank.
b).
Syphon filling from a water container
: Fresh water hose
should be connected to the SANITIZE inlet, other end of the
hose placed in a bucket of water. Colored valves should be in
SANITIZE position. Turn the pump ON and water will be
siphoned into the tank.
DO NOT OVERFILL THE TANK!
Use the LED indicators on the tank monitor at the
Command Center to monitor water level in fresh water
tank.
2.
Power to water heater should be OFF (electric and LP Gas switch-
es on standard storage water heater). Set the
red water heater bypass lever to
NORMAL
.
(lever points left)
3.
When the fresh water tank is full, set the
valves to the
DRY CAMPING
setting. Turn
the pump ON to send water through the lines.
NOTE:
To thoroughly sanitize the fresh water tank, the unit should
be driven around for a short distance allowing the solution to splash
the sides and top of the tank.
Summary of Contents for EAGLE FW 2020
Page 1: ...Owner s Manual 0283662 2020 2020 Fifth Wheel Towables FW FW HT and FW HTX ...
Page 2: ......
Page 4: ......
Page 12: ... 10 ...
Page 40: ...Section 3 Pre Travel Information 38 Notes ...
Page 64: ...Section 4 Vehicle Operation 62 Notes ...
Page 112: ...Section 7 Fuel Propane System 110 ...
Page 156: ...Section 8 Plumbing System 154 Notes ...
Page 160: ...Section 9 Heating Cooling 158 Notes ...
Page 172: ...Section 10 Appliances 170 Notes ...
Page 174: ...Section 11 Electronics 172 Notes ...
Page 196: ...Section 14 Travel Camping Storage Checklists 194 Notes ...
Page 201: ...Section 15 Additional Information 199 Notes ...