SECTION 7 - FUEL & PROPANE SYSTEM CLASS C MOTOR HOME
7 - 4
The following labels should be kept permanently affixed to the motor home.
Fig. 7.2 Propane label
Maintenance
Although both Jayco and your selling dealer carefully test for leakage, travel
vibrations can loosen fittings. Have the vehicle propane system checked at all
connections soon after the purchase of your vehicle, and after the initial filling of
the propane tanks.
NOTE
: All propane lines have been checked with air pressure at the time of
manufacture. Dealers are required to recheck and adjust pressure before retail
delivery.
Continued periodic checks of the propane system at 5,000 miles of travel (or at
least once a year), by a qualified propane service representative as part of your
normal maintenance is recommended. Hand tighten the LP gas system valves
only, do not use a wrench or pliers as over tightening may damage the valve seals
and cause them to leak.
P
ROPANE
L
EAK
T
EST
Leaks may be found easily with a soapy water solution. Do not use a solution
containing ammonia or chlorine when locating leaks. These products are
corrosive to copper gas lines and brass fittings, which could result in deterioration
of the copper and brass components.
Apply the soapy solution to the outside of the gas piping fittings. If a leak is
present, the soapy solution will “bubble” at the leak point.
DANGER
ALL PILOT LIGHTS, APPLIANCES, AND THEIR IGNITORS
(SEE OPERATING INSTRUCTIONS) SHALL BE TURNED OFF
BEFORE REFUELING OF MOTOR FUEL TANKS AND/ OR
PROPANE CONTAINERS.
FAILURE TO COMPLY COULD RESULT IN DEATH OR
SERIOUS INJURY.
WARNING
DO NOT FILL PROPANE CONTAINER(S)
TO MORE THAN 80 PERCENT OF
CAPACITY.
FAILURE TO COMPLY COULD RESULT IN DEATH OR
SERIOUS INJURY.
CAUTION
THIS PIPING SYSTEM IS DESIGNED FOR USE WITH
PROPANE ONLY. DO NOT CONNECT NATURAL GAS TO THIS
SYSTEM.
Securely cap this inlet when not connected for use. After turning
on propane, except after normal cylinder replacement, test
propane piping and connection to appliances for leakage with
soapy water or bubble solution. Do not use products that contain
ammonia or chorine.
DD-37
Summary of Contents for CLASS C2013 GREYHAWK
Page 1: ...2013 GREYHAWK CLASS C MOTORHOMES 0188485 2013...
Page 2: ......
Page 8: ...TABLE OF CONTENTS GREYHAWK CLASS C VI THIS PAGE IS INTENTIONALLY BLANK...
Page 26: ...SECTION 1 WARRANTY SERVICE CLASS C MOTOR HOMES 1 18 THIS PAGE IS INTENTIONALLY BLANK...
Page 98: ...SECTION 10 APPLIANCES CLASS C MOTOR HOME 10 4 THIS PAGE IS INTENTIONALLY BLANK...