![background image](http://html1.mh-extra.com/html/jayco/alante-2021/alante-2021_owners-manual_3505455029.webp)
27
Section 2: Occupant Safety
any combustion equipment not inspected by the technician and consult the manufacturer’s
instructions or contact the manufacturer directly for more information about carbon monox-
ide safety and this alarm.
Alarm features and functions
Includes an 85db audible horn, two LEDs, and a SILENCE/TEST button.
Alarm States
Normal operation:
The Green LED is ON steady. Red LED OFF, Audible horn
OFF.
Power OFF:
Both LEDs and the audible horn will be OFF.
Self Test:
Green LED OFF, Red LED ON/Flashing, audible horn 4 chirps fol-
lowed by constant beeps.
CO alarm condition:
Green LED OFF, Red LED Flashing, audible alarm 4
chirps.
Propane gas alarm:
Green LED OFF, Red LED ON, audible alarm constant
beeps.
Alarm Silenced (5 min
.
max.) Green LED OFF, Red LED flashes each second,
Audible horn OFF.
Low Battery (Below 8VDC):
Green LED flashes each minute, Red LED flashes
each minute, audible horn chirps each minute.
End of life or other failure:
Green and Red LEDs will double flash every min
-
ute, audible horn chirps each minute. The alarm should be replaced as soon as
possible.
Maintenance
Vacuum the alarm cover at least once a year. Clean the cover by hand using a cloth damp-
ened in clean water. Dry with a soft cloth. Do not spray the front panel of the alarm with
cleaning agents or waxes. This action may damage the sensor causing an alarm or cause the
alarm to malfunction. Do not paint the face of the alarm.
Testing the combination carbon monoxide/propane alarm
The SILENCE/TEST button tests both sensors and battery voltage. The SILENCE/TEST
button is located on the front of the alarm. Press and hold the test button for 1 second. The
alarm performs 2 cycles of the CO horn pattern (4 rapid chirps followed by a 4 second pause)
followed by 2 cycles of the Propane horn pattern (constantly beeping). Green LED is OFF,
Red LED is ON/flashing.
Repair or replace the combination carbon monoxide/propane alarm when the alarm no lon-
ger functions. As with any electronic product, it has a limited life. Alarms that do not work
cannot protect you.
Test the alarm operation after the motorhome has been in storage, before each
trip and at least once per week during use.
NOTE:
Pressing the test button does not check the sensor operation.
Refer to the carbon monoxide/propane alarm manufacturers user’s manual
provided with your recreation vehicle for additional information on testing the
sensors.
Table of Contents
Maintenance Record
Summary of Contents for Alante 2021
Page 1: ...Class A Motorhome Owner s Manual 0253835 2021 2021 Asubsidiary of Thor Industries Inc...
Page 2: ......
Page 8: ......
Page 32: ...30 Section 2 Occupant Safety Notes Table of Contents Maintenance Record...
Page 38: ...36 Section 3 Pre Travel Information Notes Table of Contents Maintenance Record...
Page 154: ...152 Section 13 Exterior Notes Table of Contents Maintenance Record...
Page 158: ...156 Section 14 Travel Camping Storage Checklists Notes Table of Contents Maintenance Record...
Page 162: ...160 Section 15 Additional Information Notes Table of Contents Maintenance Record...