SECTION 8
PLUMBING SYSTEM
51
W
ATER
P
RESSURE
R
EGULATOR
(C
USTOMER
S
UPPLIED
)
Excessive pressure from water supply
systems may be encountered in some parks,
especially in mountain regions. Water
pressure regulators are available to protect
your system against such high pressure. A
regulator of this type is recommended to
prevent damage to the plumbing system or
components. Water pressure regulators
(customer supplied) are available from your
RV dealer to protect the RV plumbing system
against such high pressure.
12-V
OLT
W
ATER
P
UMP
&
S
WITCH
Once activated, the water pump (also known
as the demand pump) will self-prime, and
provide water. The water pump continues to
run until approximately 45 lbs. of pressure is
achieved and shut off. The water pump will
automatically re-start when pressure drops.
Some cycling may occur, depending on the
volume of water being released. The water
pump is engineered by the OEM with a check
valve to prevent water from back flowing into
the fresh water supply tank
Dry camping
When you want to use water in your RV and
the RV is not hooked up to city water, you will
need sufficient 12-volt DC power to run the
water pump. Depending on your trailer model,
the pump will be located under the bed, in a
cupboard, under the unit or under the sink.
The switch to operate the water pump is
located on the monitor panel or an interior
wall.
The water pump switch should be in the
OFF position when the RV is left
unattended for any amount of time. If
something would happen to the water
system, this may help limit water damage
to a smaller area.
Periodically check the in-line water pump
strainer for accumulated debris. To clean,
shut off the water pump, unscrew the clear
cap, remove the re-useable metal strainer and
clear any debris, then reinstall.
W
ATER
H
EATER
The water heater is designed to heat water
quickly and efficiently. The water heater
manufacturer has preset the sensing limit to
maintain the water temperature when the
water heater is activated. Hydrogen gas in the
water lines may result if you have not used
the water heater for two weeks or more. To
reduce the risk of injury under these
conditions, open the hot water faucet for
several minutes at the kitchen sink before you
use any electrical appliance connected to the
hot water system. If hydrogen is present, you
probably will hear an unusual sound such as
air escaping through the pipe as the water
begins to flow. Hydrogen gas may be present
even after water has been drained from the
tank. Open faucet at the sink and allow
system to vent for five to ten minutes (or as
needed).
Not using a water pressure regulator when
using city water may cause the o-rings to
fail. To prevent damage to the plumbing
system or components when using the city
water connection, a water pressure
regulator rated for 40 lbs. is
recommended.
Do not replace any component part with an
accessory part that is not authorized by the
water heater manufacturer, such as an
“add-on” electric heating element. Such
items are not approved to be installed and
could create an unsafe condition and will
void all warranties.
Fig. 8.3 Water
pump strainer
Summary of Contents for 2009 Octane ZX
Page 1: ...www jayco com Sport Utility Trailer Owner s Manual Model Year 2009...
Page 9: ...SECTION 1 WARRANTY SERVICE 5...
Page 12: ...SECTION 1 WARRANTY SERVICE 8...
Page 13: ...SECTION 1 WARRANTY SERVICE 9...
Page 14: ...SECTION 1 WARRANTY SERVICE 10...
Page 16: ...SECTION 1 WARRANTY SERVICE 12...
Page 17: ...SECTION 1 WARRANTY SERVICE 13...
Page 18: ...SECTION 1 WARRANTY SERVICE 14...
Page 42: ...SECTION 5 RV TIRES 38 THIS PAGE IS INTENTIONALLY BLANK...
Page 52: ...SECTION 7 FUEL SYSTEM 48 THIS PAGE IS INTENTIONALLY BLANK...
Page 70: ...SECTION 9 PROPANE SYSTEM 66 THIS PAGE IS INTENTIONALLY BLANK...
Page 84: ...SECTION 11 CAMPING OPERATING 80 THIS PAGE IS INTENTIONALLY BLANK...
Page 102: ...SECTION 13 SPECIFICATIONS GLOSSARY 98 THIS PAGE IS INTENTIONALLY BLANK...