3-2. Functional push button

 

           

Push button 

Function 

Func 

“FUNC”

 key is the function select key that acts with trigger. 

Use the key as switch of    DC/AC current, Diode/Continuity 
and 

/

 

 HOLD 

Press 

“HOLD

” to enter and exit the hold mode in any mode. 

That act with trigger.   

Hz% 

This key is act with trigger the duty function 

 

  

This key is used control Backlight. This key is act with 
trigger.    When press and hold the key over 2 sec, will enable 
Backlight.   
Press the key again , the backlight will disable.       

 

3-3.  Display indicators                                 

 

Fig. 2 LCD

 

 

Number  Indicator  

Meaning  

 

DC voltage or current   

 

AC voltage or current 

 

Diode  

4 MAX 

Maximum 

value 

 

 

     HOLD 

Data hold 

 

Low battery indicator 

7 MK

Ω

 

Ω

  K

Ω

  M

Ω

  is unit of resistance 

 

The unit of temperature   

: Fahrenheit) 

µ

mVA 

  mV ,V is unit of voltage 

µ

A, mA, A is unit of current 

10 

 

Indicate negative reading   

11 

Hz 

Frequency Unit 

12 

nF,

 µF

 

Capacitance unit 

 
 
 
 
 

                           

 
 

 

 

                                                                       

Summary of Contents for QM1327

Page 1: ...4 1 General Specification 4 1 Electrical Specification 5 Measurement operation 5 1 DC voltage AC voltage measurement 5 2 Resistance measurement 5 3 Diode Continuity check 5 4 Frequency Measurement 5 5...

Page 2: ...and grounding terminal Do not apply voltage between COM and OHM terminal in the resistance measuring state Do not measure current with test lead inserted into voltage or OHM terminal Do not expose the...

Page 3: ...tribution boards circuit breaker and industrial equipment located in fixed facilities as a fixed motor 3 Explanation of controls and indicators 3 1 Meter illustration NCV indicator LED LCD display Hz...

Page 4: ...rol Backlight This key is act with trigger When press and hold the key over 2 sec will enable Backlight Press the key again the backlight will disable 3 3 Display indicators Fig 2 LCD Number Indicator...

Page 5: ...ting temperature Humidity 0 40 32 104 80 RH Storage temperature Humidity 10 50 14 122 70 RH Power Supply 9V Battery 6F22 or 1604A Type x 1pc Safety Class IEC 61010 1 CAT III 600V Dimension L x W x H W...

Page 6: ...nd use the fuse F10A H 250V at 10A range Max input current 200mA at mA input terminal and 10A at 10A input terminal 4 2 7 AC Current Range Resolution Accuracy 400 A 0 1 A 4000 A 1 A 1 2 rdg 4dgt 40mA...

Page 7: ...V input terminal and the black test lead into the COM terminal 2 Set the rotary switch to DC or AC range 3 Connect the test lead across with the object under testing The measured value will be show on...

Page 8: ...red test lead on the component anode and place the black test lead on the component cathode The measured value show on the display Reverse the test lead and measure the voltage across the diode again...

Page 9: ...Capactiance measurement 4 Set the rotary switch to capactiance position 5 Insert the red test lead into the V Hz input terminal and the black test lead into the COM terminal 6 Connect the test leads a...

Page 10: ...sert a new fuse of the same size and rating F400mA H250V or F10A H250V iii Replace the bottom case and reinstall all the screw 6 3 Test lead replacement The test lead has been used and replaced shall...