Page
2
of
2
3. Device Connections
a. JMT via Bluetooth:
Connect the TRIUMPH-3NR to JMT using Bluetooth. Open JMT and click on the connection
icon in the
upper right corner to open the ‘Connections screen. Select the
TRIUMPH_3NR_[S/N] with the Bluetooth radio check box enabled (Figure 1).
Figure 1: JMT Bluetooth Connection
b. NetView&Modem via USB:
Connect the TRIUMPH-3NR to NetView&Modem using the USB cable (Micro B type, labeled
14-578156-01). Open NetView&Modem and select the USB device port (Figure 2).
Figure 2: NetView&Modem USB Connection
4. Data Logging
Start and stop data logging directly on the TRIUMPH-3NR with the data logging button (Figure
3).
Figure 3: Data Logging Button
Press and hold the data logging button between 1
– 5 seconds to start / stop data logging.
Start and stop data logging in JMT (Under Survey Settings), or in NetView&Modem (under the
Files menu).
5. Antenna Name
The TRIUMPH-
3NR’s Antenna Name is “
JAVTRIUMPH_3NRA
”. The antenna name is used to
call calibrated antenna phase center offsets.