www.javad.com
Maxor Operator’s Manual
3-15
S E T U P A N D M E A S U R I N G
Measuring with the Maxor
9. Select the
Positioning
tab and set the Position Masks, Elevation
mask parameter to 15 (Figure 3-10).
Figure 3-10. Receiver Configuration – Positioning
10. Select the
Base
tab and set the following parameters (Figure 3-11
• GPS/GLO at one time - enable
• Antenna position - enter Lat, Lon, and Alt values. Do one of the
following:
–If known, type in the values.
–Click
Get from receiver
.
–Enable Averaged and enter the Averaged Span in seconds, then
click
Apply
. Click
Tools->Reset receiver
and wait until the
specified interval (span) completes. Examine the Base coordinates
on the Base tab, they should correspond to the coordinates obtained
from the average. Click
Refresh
if the coordinates are zeros.