2-34
Maxor Operator’s Manual
www.javad.com
C O N F I G U R A T I O N
Radio Configuration
2
Notice:
The settings must be the same for base and rover.
2. Click on the
FCS
tab (Figure 2-26).
Figure 2-26. FCS Tab
3. From the
Mode
control, select
Slave
.
4. In the
Free Scan Frequency List
control, you will see the
frequencies that are used in the scan process. Double-click a
frequeny in the list to exclude/include this frequency from/to the
scan process. You may also select/deselect all frequencies at one
time with the
Select all
and
Deselect all
controls.
Notice:
For FCS to operate properly, you must select at least two
frequencies. Also the selected frequencies must be the
same as at the base radio modem.
5. In the
Time Out
edit box, specify a period in seconds within which
the rover radio-modem will listen to the incoming data on the
current operating frequency. Should there be no any data detected
during the specified amount of time, the rover will switch to the
next frequency in the list and so forth until the frequency with data
is found.
Notice:
It is recommended to make this parameter greater than
the base radio modem’s Time out by 2 to 3 seconds.
Summary of Contents for Maxor
Page 2: ......
Page 12: ...viii Maxor Operator sManual www javad com Notes ...
Page 34: ...1 16 Maxor Operator s Manual www javad com Notes ...
Page 126: ...4 28 Maxor Operator s Manual www javad com Notes ...
Page 138: ...5 12 Maxor Operator s Manual www javad com Notes ...
Page 156: ...B 16 Maxor Operator s Manual www javad com Notes ...
Page 160: ...C 4 Maxor Operator s Manual www javad com Notes ...
Page 164: ...E 2 Maxor Operator s Manual www javad com Notes E ...