4-4
Maxor Operator’s Manual
www.javad.com
O P E R A T I O N
Using MinPad
4
• After loading new firmware or clearing the receiver's NVRAM, the
receiver checks its internal file system.
During this operation, the REC LED flashes orange, and the file system
is not accessible for CDU (control display unit) applications or for data
recording. This operation may require from fractions of a second to
several minutes, depending on the circumstances and the amount of
internal memory.
Table 4-1. FN Key Functions and REC LED Status
FN Key
REC LED
Status
When data recording is OFF, and the FN key is...
Not pressed
No light
No data recording.
Orange blink
Internal file system test in progress.
Red
No free memory; hardware problem with
data recording.
Pressed for < 1 second
If FN key mode is «LED blink mode switch»
Orange
Release to charge information mode.
If FN key mode is «Occupation mode switch»
Orange
No function.
Pressed for 1–5
seconds
If FN key mode is «LED blink mode switch»
Green
Release to start data recording (post-
processing occupation mode undefined).
If FN key mode is «Occupation mode switch»
Green
Release to start recording (Kinematic or
Static post-processing occupation mode).
Pressed for 5–8
seconds
Red
Release to turn serial port A baud rate to
9600 bps.
Pressed for > 8
seconds
No light
No function.
Summary of Contents for Maxor
Page 2: ......
Page 12: ...viii Maxor Operator sManual www javad com Notes ...
Page 34: ...1 16 Maxor Operator s Manual www javad com Notes ...
Page 126: ...4 28 Maxor Operator s Manual www javad com Notes ...
Page 138: ...5 12 Maxor Operator s Manual www javad com Notes ...
Page 156: ...B 16 Maxor Operator s Manual www javad com Notes ...
Page 160: ...C 4 Maxor Operator s Manual www javad com Notes ...
Page 164: ...E 2 Maxor Operator s Manual www javad com Notes E ...