www.javad.com
LGG100-GG Operator’s Manual
67
O P E R A T I O N
Clearing the NVRAM
Using MinPad to Clear NVRAM
1. Press the
power
key to turn off the receiver.
2. Press and hold the
FN
key.
3. Press and hold the
power
key for about one second. Release the
power
key while continuing to hold the
FN
key.
4. Wait until the STAT and REC LEDs are green
5. Wait until the STAT and REC LEDs blink orange.
Release the
FN
key while the STAT and REC LEDs blink orange.
Using PCView to Clear NVRAM
1. Connect your receiver and computer. See “Connecting the LGG100-
GG and a Computer” on page 27 for this procedure.
2. Start PCView.
3. Click
Tools->Clear NVRAM
4. Click
OK
at the clear NVRAM confirmation dialog box.
Figure 4-12. Tools->Clear NVRAM
The receiver will automatically disconnect once the NVRAM is cleared.