Before starting: - 

 
Add vacuum pump oil and always check the oil level before use. Low oil level or poor 
quality oil will result in premature wear and poor performance. 
Install on a flat surface with adequate ventilation; allow 5cm on all sides of the pump. 
Remove the intake and exhaust fitting cap and connect via a suitable hose to a 
manifold or suitable circuit. 
Connect to a suitable safe power source using earth leakage devices when using 
extension cords. 
 

 

     Caution: 

1)  Do not use with combustible, explosive, poisonous or reactive/corrosive 

gases. 

2)  Do not allow dust particles to enter the pump. 
3)  Do not allow the pump to run to open air / atmosphere for more than 3 

minutes; 

4)  Do allow the inlet temperature of gases to exceed 80

°

C. Do not use in 

environments over 50

°

C; 

5)  Not suitable for use as a compressor, transfer pump or recovery pump.   
6)  Do not operate without oil. 
7)  Pump surface may be hot. 
8)  Do not block air outlet when pump is in use. 
9)  Suitable for indoor use only. 

.  
 

Refrigeration service tools

 4 - 

Summary of Contents for CC Series

Page 1: ...CC Series VACUUM PUMPS OPERATING MANUAL ...

Page 2: ...o m p o n e n t s 3 III B e f o r e s t a r t i n g 4 IV T r o u b l e S h o o t i n g 5 V Exploded Drawing 6 VI W a r r a n t y 7 VII S e r v i c e To o l s 8 Application CC series two stage oil sealed rotary vane vacuum pumps are basic equipment to evacuate domestic automotive and light commercial refrigeration and AC equipment They are suitable for use with R134a R22 and compatible refrigerants...

Page 3: ... 240v 50Hz 220 240v 50Hz 220 240v 50Hz Free Air Displacem ent 36 l min 76 l min 132 l min 176 l min 225 l min Ultimate Vacuum 25Micron 25Micron 25Micron 25Micron 25Micron Motor 1 4 Hp 1 3 Hp 1 3 Hp Hp 2 3 Hp Motor Speed 1440 r m 1440 r m 2880 r m 2880 r m 2880 r m Oil Capacity 350 ml 380 ml 450 ml 500 ml 500 ml Dimensions 330x135x255 mm 350x143x265 mm 350x143x265 mm 380x160x285 mm 380x160x285 mm N...

Page 4: ...source using earth leakage devices when using extension cords Caution 1 Do not use with combustible explosive poisonous or reactive corrosive gases 2 Do not allow dust particles to enter the pump 3 Do not allow the pump to run to open air atmosphere for more than 3 minutes 4 Do allow the inlet temperature of gases to exceed 80 C Do not use in environments over 50 C 5 Not suitable for use as a comp...

Page 5: ... damaged Replace with a new oil seal Oil leakage 2 Oil casing gasket loose or damaged Tighten screws or replace O type ring 1 Too much oil Drain oil to oil base line on sight glass Oil discharge 2 Inlet pressure too high Use recovery pump to remove pressure 1 Temperature below 5C Allow temperature to rise 2 Motor overloaded Wait 5 minutes re start or press motor reset if installed 3 Foreign matter...

Page 6: ...e 21 Cap like cover 10 Rotary vane spring 22 Trestle 11 Back pump rotor 23 Handle 12 Valve piece 24 Sleeve 31 Shaft seat 13 Back pump stator 25 Cover 32 Motor Stator 14 Middle fence 26 Capacitor 33 Bearing 15 Molded base 27 Board 34 Motor rotor 16 Restricting piece 28 Switch 35 Motor cover 17 Front pump rotor 29 Motor hull 36 Fan 18 Front pump stator 30 Outlet 37 Fan cover Refrigeration service to...

Page 7: ...imited to at its option repairing or replacing the defective machine or part This WARRANTY is in lieu of all other warranties express or implied whether of MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE or otherwise All such other warranties are expressly disclaimed JAVAC shall have no liability in excess of the price paid to JAVAC for the machine plus return transportation charges prepaid JA...

Page 8: ...achines Recycle Machines Charging Units Leak Detectors Manifolds Hoses Tools Accessories Javac UK Limited Europe Office Unit 6 Drake Court Britannia Park Middlesbrough TS2 1RS United Kingdom Tel 44 1642 232880 Fax 44 1642 232870 Javac Supplying the world with Vacuum Refrigeration Process lutions So Refrigeration service tools 8 ...

Reviews: