background image

 

Page 10 

www.jatontec.com 

 

 

Summary of Contents for JT6300D

Page 1: ...Page 1 www jatontec com JT6300D LTE Outdoor CPE Administrator User Manual V1 0 ...

Page 2: ...the voltage of the power source matches the requirements of the instrument The unit must be standards Disposal and Recycling Information Pursuant to the WEEE EU Directive electronic and electrical waste must not be disposed of with unsorted waste Please contact your local recycling authority for disposal of this product Reduction of Hazardous Substances This CPE is compliant with the EU Registrati...

Page 3: ...1 PLMN SELECTION 11 CELL SELECTION 12 PDN SETTING 12 SIM CARD 13 ADVANCED 13 LTE SMS 14 COMMAND SHELL 15 5 NETWORK CONFIGURATION 16 INTERNET 16 LAN SETTING 17 VPN SETTING UNDER ROUTER MODE 18 VPN SETTING UNDER L2 BRIDGE MODE 20 L2 SERVICE UNDER L2 BRIDGE MODE 20 QOS SETTING 21 DDNS SETTING UNDER ROUTER MODE 21 TRAFFIC CONTROL SETTING UNDER ROUTER MODE 22 6 SECURITY CONFIGURATION 22 FIREWALL 22 ALG...

Page 4: ...7 PORT TRIGGERING 28 8 MANAGEMENT 28 DEVICE MANAGEMENT 28 TR069 29 9 MAINTENANCE 30 GENERAL 30 FIRMWARE UPGRADE 31 CONFIG MANAGEMENT 31 PING 32 IPERF 32 SYSTEM RESET 33 10 STATUS 34 SYSTEM 34 NETWORK 35 LAN 36 11 FAQ AND TROUBLESHOOTING 37 ...

Page 5: ... 13dBi 4 4 MIMO 1 RJ45 10 100 1000M LAN Port PWR SYS SIM LINK ACT and LTE 1 5 LEDs 48V 0 5A PoE supply ODU Power 15 Watts Dimensions 250 mm L 250 mm W 75 mm D Weight 2 5 Kg 2 Getting Started 1 Packing list Upon receiving the product please unpack the product package carefully Each product is shipped with the following items Table 2 1 Packing List Outdoor CPE Products Quantity ODU unit 1 PoE adapte...

Page 6: ...power supply adapter The power adapters can operate in 100 240V AC range and therefore can be used in different country Once the device is powered up the user should wait for about 1 minutes before the device becomes operational When the RF1 LED becomes blinking green it indicates the system has completed the startup procedure To connect PC LAN switch or other type of IP device to the CPE product ...

Page 7: ...Page 7 www jatontec com Installing Mounting brackets Header Connection ...

Page 8: ...signal strengths indication by 5 green LEDs 1st Green LED 115dBm RSRP 2nd Green LED 115dBm RSRP 105dBm 3rd Green LED 105dBm RSRP 95dBm 4th Green LED 95dBm RSRP 85dBm 5th Green LED 85 RSRP RF Signal Adjustment After the CPE outdoor unit has installed the direction of antenna s azimuth and pitch angle needs to adjust for the best signal strength In near line of sight condition the CPE will have the ...

Page 9: ...the device After IP connectivity is established between the PC and CPE device the user may launch a Web browser and specify http 10 1 1 1 in the address bar A window will pop up requesting password Input the user or administrator login password and then click the Log in button After successful log on the default home page will appear Note the default user administrator passwords are user123 and ad...

Page 10: ...Page 10 www jatontec com ...

Page 11: ...via Reconnect Note After configure any parameters of the device you must click the Save Apply button to save the configuration Otherwise the configuration will not take effect PLMN Selection The user can add and configure the PLMN list to restrict the CPE to attach The CPE will attach to network according to the PLMN priority assigned ...

Page 12: ...ndard When configured with preferred Listing user add the desired cell ID to the list and the CPE will attach to the appropriate cell after a full scan PDN Setting This menu is used to configure the operator APN profile You can configure single or multiple APNs for the operator network The below shows an example of two APN configuration You can view the APN status info in the Status menu ...

Page 13: ...ound instead of search the best cell The ZUC encryption support is only required when your core network EPC force to use the ZUC encryption for access authentication The operation mode allows you to select the UE capability for receiving and transmitting Depending on the hardware implementation 4x4 MIMO or 2x2 MIMO CA can be selected for downlink operation If the RF hardware supports 2TX then 2Tx ...

Page 14: ...tontec com LTE SMS The LTE SMS page allows user to retrieve and display short messages received by the UE device Message format storage place and message filter can be configurere to screen and archieve the messages ...

Page 15: ...Page 15 www jatontec com Command Shell The Command Shell is used to run LTE command via the WEB GUI interface You can type the command and click the APPLY button to execute ...

Page 16: ...ress via DHCP server of the device The default MTU Size is 1500 user can modify the MTU Size if necessary Note when setting the connection mode as L2 Bridge or L3 Bridge there will be a warning window pops up Remember the management IP address 10 1 1 1 and click the ok button When the user wants to manage the home page again the PC should be configured a static IP address as 10 1 1 x manual in ord...

Page 17: ...lows user to specify the device LAN IP DHCP server setting Local DNS and etc When Router mode is selected the DHCP server should be enabled by default User is advised to leave the default setting unchanged for quick configuration and smooth device operation ...

Page 18: ...service for selected connection mode In router mode PPTP L2TP and GRE can be selected In L2 Bridge mode only L2 GRE can be configured The router mode VPN configuration is shown below The PPTP configuration under router mode is shown below The L2TP configuration under router mode is shown as follows ...

Page 19: ...Page 19 www jatontec com The L2 GRE configuration under router mode is shown below ...

Page 20: ...e Mode Under the L2 Bridge connection mode only L2 GRE can be configured as follows L2 Service Under L2 Bridge Mode Under the L2 Bridge connection mode the user can use L2 Service configuration to manage and tag 802 1p or DSCP for different VLAN packets ...

Page 21: ...configuration menu allows user to tag DSCP or TOS value for CPE local data Management and LAN port data Data DDNS Setting Under Router Mode This configuration menu allows user to configure use of different DDNS service for router mode operation ...

Page 22: ...raffic Control Setting Under Router Mode This configuration menu allows user to configure the data priority and allowed bandwidth for LAN data traffic 6 Security Configuration Firewall This allows user to configure CPE firewall ...

Page 23: ...Page 23 www jatontec com ALG This allows user to configure the application level gateways for many common applications ...

Page 24: ...Page 24 www jatontec com Defense This allows user to configure defense policy for the LTE and local LAN interface to prevent hostile attack ...

Page 25: ...Page 25 www jatontec com Access Restrictions This allows user to define access policy for LAN devices It can support URL blocking as well ...

Page 26: ...ations Configuration Port Range Forwarding This allows user to configure the port range forwarding rules for the CPE in router mode Port Forwarding This menu allows user to configure the port forwarding rules for the CPE in router mode ...

Page 27: ... SSH and Ping Service port can be exempted from DMZ mapping if required By enabling DMZ option will make the specified local LAN host DMZ IP exposed to Internet UPnP This menu allows user to configure the uPnP application for on demand DMZ support The current forwarding rules created can be viewed and cleared if required ...

Page 28: ...d certain port range to different port range for specific protocol 8 Management Device Management The menu allows user to configure device management mode and various control Telnet SSH and HTTPs can be enabled or disabled via configuration Auto WEB GUI logout can also be configured ...

Page 29: ...et is enabled user can telnet to CPE according to the below steps cmd shell and run command telnet 10 1 1 1 Login root Password root123 TR069 The menu allows user to configure the necessary setting for TR069 management of the CPE device ...

Page 30: ...Page 30 www jatontec com 9 Maintenance General The menu allows user to configure the WEB GUI login password time and language setting ...

Page 31: ... menu allows user to perform firmware upgrade via WEG GUI with option to reset to factory setting It can also configure the remote upgrade using FTP TFTP or HTTP Config Management This menu allows user to backup or restore device configuration file ...

Page 32: ...to perform PING tests using WEB GUI interface Both IPv4 and IPv6 can be supported Iperf This menu allows user to configure iPerf testing using WEB GUI interface Both TCP and UDP tests can be supported Remote iPerf server is required to conduct the tests ...

Page 33: ...Page 33 www jatontec com System Reset This menu allows user to reboot the device or restore the device to factory defaults Special care needs to be taken when restoring factory defaults ...

Page 34: ...Page 34 www jatontec com 10 Status System The menu shows the general system info of the CPE device It includes connection system CPE and memory usage information ...

Page 35: ...Page 35 www jatontec com Network The menu shows the general network status that includes PDN interface info device routing info and ARP table ...

Page 36: ...Page 36 www jatontec com LAN The menu shows the local LAN network status including the LAN interface and DHCP Server setting and current DHCP clients connected ...

Page 37: ... NIC IP should be manually configured to be 10 1 1 X 255 255 255 0 in order to gain access to the device WEB GUI When you are done with the device configuration the PC NIC IP should be reconfigured to use DHCP for proper LTE networking If the problem persists please contact the operator or distributor for further diagnose 3 My CPE networking is not working properly You may want to check if the LTE...

Reviews: