JASON Hydrotherapy AirMasseur Madeline MA635P Owner'S Manual Download Page 16

Jason International, Inc.  •  

 

501.771.4477  

 

 

 

Page 16 of 16

 

 

 

 

Customer Service :  800.255.5766 

Copyright © 2011 Jason International.

IMPORTANT SAFETY INSTRUCTIONS

INStRuCtIONS PERtaININg tO thE RISK Of fIRE, ElECtRIC ShOCK, OR INJuRY tO 

PERSONS.

This manual contains information and instructions for proper operation and maintenance of your therapy bath.  Failure to 
follow these instructions could result in personal injury, electrical shock, or fire.

WaRNINg:  When  using  this  unit,  basic  precautions  should  always  be  followed,  including  the 

following:

REaD aND fOllOW all INStRuCtIONS CaREfullY

DaNgER:

 

tO REDuCE thE RISK Of INJuRY fOllOW thESE PRECautIONS: 

a.

  Do not permit children to use this product unless they are closely supervised at all times.

b.

  Use this unit only for its intended use as described in this manual. Do not use attachments not recommended by the 

manufacturer.

C.

  The water in a  therapy bath should never exceed 104°F (40°C). Water temperatures between 100°F (38°C) and 104°F 

(40°C) are considered safe for a healthy adult. Use time should be limited to approximately 30 minutes, followed by 
a shower to cool down. Longer exposures may result in hyperthermia. The symptoms of this condition are nausea, 
dizziness and fainting, and it can be fatal. Lower water temperatures are recommended for extended use (exceeding 
10 -15 minutes) and for young children.

D.

  Since excessive water temperatures have a high potential for causing fetal damage during the early months of pregnancy, 

pregnant or possibly pregnant women should limit therapy bath water temperatures to 100°F (38°C).

E.

  The  use  of  drugs  or  alcoholic  beverages  before  or  during  therapy  bath  use  may  lead  to  unconsciousness  with  the 

possibility of drowning. Never use the therapy bath while under the influence of alcohol, anticoagulants, stimulants,  
antihistamines, vasoconstrictors, vasodilators, hypnotics, narcotics, or tranquilizers.

f.

  Persons with a medical history of heart disease, low or high blood pressure, circulatory system problems, or diabetes 

should consult a physician before using a therapy bath.

g.

  Persons using medication should consult a physician before using a therapy bath since some medication may induce 

drowsiness while other medication may affect heart rate, blood pressure, and circulation.

DaNgER:

 

 

to reduce the risk of injury, enter and exit the bath slowly. 

WaRNINg:

 Never operate electrically connected devices in or near the bath. Never drop or insert any object into any opening.

This unit must be connected to a supply circuit that is protected by a GFCI. Such a device should be installed by a licensed 
electrician and should be tested on a regular basis (at least monthly). To test the GFCI push the 

tESt

 button. The GFCI 

should interrupt the power. Push the 

RESEt

 button and the power should be restored. If the GFCI fails to operate in this 

manner, there is the possibility of an electric shock. 

DO NOt uSE. 

Disconnect the unit and have the problem corrected by a 

qualified service technician. 
To avoid the possibility of personal injury and discoloration of the acrylic surface, the inlet water temperature should not 
exceed 104°F (40°C). The bath should be drained after each use. Each bather should start their bath with fresh water. Do 
not use oil base additives in your therapy bath.

CautION: Do not use harsh abrasives or solvents for cleaning this unit.

INStallER/OWNER bEaRS all RESPONSIbIlItY tO COmPlY WIth all StatE  

aND lOCal CODES WhEN INStallINg thIS PRODuCt.

SaVE thESE INStRuCtIONS

 

Jason InternatIonal, Inc.

8328 MacArthur Drive  •  North Little Rock  •  Arkansas  •  72118

www.jasoninternational.com 

Summary of Contents for AirMasseur Madeline MA635P

Page 1: ... in writing with a request for a representative to inspect the unit Failure of the carrier to respond should be reported to the seller and carrier Always file a freight claim promptly The installer is responsible for insuring that the unit is free from defects or shipping damage In the event of a problem DO NOT install the unit Jason International is not responsible for damage that might have been...

Page 2: ...nd skirt center lines Tape the template to the sub floor in its desired location 6 Markonthesub floor the sump area location the water inlet stub outlocation andtheremoteblower tubingfloorcutout location Two remote blower tubing floor cutout locations and water inlet stub out locations have been indicated on the template Choose the one that is preferable for your installation 7 Removethetemplatean...

Page 3: ...AUTION Only dry fit the drain and overflow tee to the P trap at this time c Disconnect the drain and overflow from the bath and leave the drain assembly free standing in the P trap 12 Align the drain with the centerline on the template See Figure 4 13 Permanently attach the drain tee to the P trap 14 Remove the template from the floor 15 Place the bath skirt into position and attach to the floor b...

Page 4: ... overhang into the well of the bath This will insure an unobstructed water flow out of the faucet when filling the bath Follow the faucet manufacturers installation instructions REMOTE MOUNTING of air blower Do not remote mount the blower and control box more than 15 feet 457 cm away from the air inlet of the bath Choose a location as close as possible to the bath to assure maximum efficiency 1 Th...

Page 5: ...les back up through the floor cutout When installing on a cement slab a conduit may be used if desired to run the cable from the bath to the control box This will allow the bath to be lifted and removed from the skirt if access is required in the future During installation if it is preferred to run the blower hose on top of the floor a 2 1 2 6 35 cm diameter hole can be drilled in the toe kick are...

Page 6: ...f the bath s Level Form Base must be level with the bottom of the skirt Note Do not use a sand bed to install or level the bath 9 Bolts a Startwithone 1 boltandliftthebathenoughtopartially install the bolts Do not tighten the bolts completely at this time Align the bolts with the slot in the bath bracket Repeat the process until all six 6 bolts are partially installed b Continue to fully tighten a...

Page 7: ... CODES MUST BE OBSERVED Where there are no local codes the National Electric Code NEC and Uniform Plumbing Code UPC shall be observed It is the responsibility of the installer owner to determine specific code compliance prior to installation of the product NOTE In the Commonwealth of Massachusetts installation is to be done by a Massachusetts licensed plumber Standard Premier Edition Control Box 1...

Page 8: ... acrylic surface during installation to minimize cleanup and prevent surface damage WATER TESTING Before finishing the installation it is recommended that the bath be water tested and the plumbing tested for leaks Before water testing the bath 1 make sure any pump unions are hand tight Do not over tighten or use a pipe wrench This will damage the unions and cause leaking If the unit leaks with the...

Page 9: ...0v systems the power cord for the Blower control box must be plugged into a 120v 15 amp GFCI dedicated circuit NOTE This diagram Figure 12 also applies to 50 Hz 240v controls and power supply systems Except that the Blower junction box must be connected into one dedicated 240v 15 Amp GFCI circuit NOTE This diagram Figure 13 also applies to 50 Hz 240v controls and power supply systems Except that t...

Page 10: ...d the blower will start again for a two minute purge cycle that dries the air channel Note that the blower light will flash during the 15 minute pause before the purge cycle begins Once the purge cycle begins all indicators will light and the keypad operation will be disabled for two 2 minutes SIGNATURE EDITION AIRMASSEUR The Jason Signature Edition AirMasseur bath includes a variable speed 1 HP a...

Page 11: ...ivating this setting Signature Remote Control In addition to the main control touchpad installed on the bath deck a floating waterproof Universal Remote Control is provided with all Signature Edition AirMasseur baths This remote control provides the same control functions as the bath s main control console plus the bather may remotely operate a TV DVD VCR CD etc Refer to the Instruction Manual pro...

Page 12: ...l LED light if installed Press the icon for less than two 2 seconds to turn the lights Off or On Hold the icon for more than two 2 seconds to change modes This function has a two 2 hour timer and remembers the last mode OPERATING INSTRUCTIONS FEATURES AND CONTROLS cont OPERATING INSTRUCTIONS AirMasseur Icon The AirMasseur icon is used to activate the blower and the 20 minute timer Pressing the Ico...

Page 13: ...NNECTIONS section Remote Control The Signature Edition control system includes a waterproof floatingUniversalRemoteControl Itcontrolsallbathfunctions plus a TV DVD CD etc which can be heard through the optional Sound Immersion Transducers optional Blower On Off Modes Blower Speeds LED Light IR for Remote OPERATING INSTRUCTIONS FEATURES AND CONTROLS cont OPERATING INSTRUCTIONS Blower On Off and Mod...

Page 14: ...erial number proof of purchase andmodelnumber Thiswillinsureaquickresponse on warranty items The serial number can be found on the front page of this manual or on the small card adhered to the back of the bath just above the equipment HUMIDITY Warning Avoid high humidity levels in your home Mold mildew fungi and bacteria which maybeharmfultohealththriveinareaswith continued high humidity levels th...

Page 15: ...FCI tripped b Refer to installer dealer Circuit breaker trips repeatedly a Defective breaker a Replace breaker b Short circuit between bath and blower breaker box b Refer to installer dealer c Other items are connected to the same circuit c Refer to installer dealer Blower does not shut off a Defective keypad or timer a Refer to installer dealer Replace keypad or control Air bath does not function...

Page 16: ...h the possibility of drowning Never use the therapy bath while under the influence of alcohol anticoagulants stimulants antihistamines vasoconstrictors vasodilators hypnotics narcotics or tranquilizers F Persons with a medical history of heart disease low or high blood pressure circulatory system problems or diabetes should consult a physician before using a therapy bath G Persons using medication...

Reviews: