![Jasic TIG180P Instruction Manual Download Page 8](http://html1.mh-extra.com/html/jasic/tig180p/tig180p_instruction-manual_3606447008.webp)
8
1
5
6
7
8
9
2
3
4
1 : Gas Pre Flow Timer
2 : Output Current Control (Main)
3 : Base CUrrent Setting
4 : Slope Out Timer
5 : Arc Force Adjustment
6 : Pulse Frequency Control
7 : Pulse Duty Control
8 : Clean Area / Width Adjustment
9 : Post Flow Adjustment
Caution
1. Working Environment
1.1 The location in which this welding equipment is installed should be free from dust, corrosive
chemical gas, flammable gas or materials, and a maximum of 80% humidity.
1.2 Avoid the operation of welding in the open air unless the working area sheltered is from the
elements. The ambient temperature of the working environment should be maintained within
–10°C to +40°C.
1.3 Allow a distance of at least 300mm (12”) between this machine and any walls.
1.4 Make sure the area you are working in is well ventilated.
2. Safety Tips
2.1 Ventilation: Good ventilation is of critical importance for the performance and service life of
this inverter welding machine. Maintain a minimum distance of 30cm (12”) between the inverter
machine and any other objects in or near the working area.
2.2 Do not operate this machine when the O.C. Light is lit.
A sudden halt may occur while the welding operation is carried out while this welding machine is
in over-load status. Under this circumstance, it is unnecessary to restart this welding equipment.
Keep the built-in fan working to bring down the temperature inside this welding equipment.
2.3 This welding equipment uses automatic voltage compensation, which enables the
maintaining of the voltage range within the given range. In case the voltage of input power