![Jasic TIG Series Operator'S Manual Download Page 10](http://html2.mh-extra.com/html/jasic/tig-series/tig-series_operators-manual_3397580010.webp)
10
TECHNICAL SPECIFICATIONS
Please Note
Due to variations in manufactured products all claimed performance ratings, capacities, measurements,
dimensions and weights quoted are approximate only. Achievable performance and ratings when in use
can depend upon correct installation, applications and use along with regular maintenance and service.
Parameter
Jasic TIG 180 DC
Unit
Jasic TIG 180 DC DV
Jasic TIG 200 DC
Rated input voltage
-
AC230V±15% 50/60Hz
V
AC115V±15% 50/60Hz
AC230V±15% 50/60Hz
-
AC230V±15% 50/60Hz
Rated input power
-
7.1
kVA
115V
-
4
230V
-
7
-
8.2
Rated input current Imax
31
A
35.6
35.6
Rated input current Ieff
-
16.5
A
115V
-
18.5
230V
-
14.2
-
18.9
Welding current range
-
-
TIG 10 ~ 180
MMA 10 ~ 160
A
115V
-
TIG 10 ~ 120
115V
-
MMA 10 ~ 100
230V
-
TIG 10 ~ 180
230V
-
MMA 10 ~ 160
-
-
TIG 10 ~ 200
MMA 10 ~ 180
No
-
load voltage
65
V
65
65
Rated duty cycle (40°C)
-
-
TIG 180A @ 35%
MMA 160A @ 35%
%
115V
-
TIG 120A @ 35%
115V
-
MMA 100A @ 35%
230V
-
TIG 180A @ 40%
230V
-
MMA 160A @ 40%
-
-
TIG 200A @ 35%
MMA 180A @ 35%
Downslope time
S
0 ~ 10
0 ~ 10
0 ~ 10
Post gas time
S
0 ~ 15
0 ~ 15
0 ~ 15
Arc ignition type
-
HF
HF
HF
Efficiency
85
%
85
85
Power factor
0.7
cos
φ
0.7
0.7
Standard
-
EN60974
-
1
EN60974
-
1
EN60974
-
1
Protection class
IP21S
IP
IP21S
IP21S
Insulation class
F
-
F
F
Noise
Db
<70
<70
<70
Operating temperature
°C
-
10 ~ +40
-
10 ~ +40
-
10 ~ +40
Storage temperature
°C
-
25 ~ +55
-
25 ~ +55
-
25 ~ +55
Overall size
365 x 135 x 277
mm
365 x 135 x 277
365 x 135 x 277
Weight
5.94
Kg
5.94
6.12