A WILKINSON STAR PRODUCT                                                                                                                                    10-17 ISSUE 3 

5  UNPACKING 

Check the packaging for any signs of damage. 
Carefully remove the machine and retain the 
packaging until the installation is complete. 

Location 

The machine should be located in a suitable 
position and environment. Care should be taken to 
avoid moisture, dust, steam, oil or corrosive gases 

Place on a secure level surface and ensure that 
there is adequate clearance around the machine to 
ensure natural airflow. 

6  CONNECTIONS 

Input connection 

Before connecting the machine you should ensure 
that the correct supply is available. Details of the 
machine requirements can be found on the data 
plate of the machine or in the technical parameters 
shown in the manual. 

The equipment should be connected by a suitably 
qualified competent person. Always ensure the 
equipment has a proper grounding. Never connect 
the machine to the mains supply with the panels 
removed. 

Output connections 

Electrode polarity 

In general when using manual arc welding 
electrodes the electrode holder is connected the 
positive terminal and the work return to the 
negative terminal. Always consult the electrode 
manufacturer’s data sheet if you have any doubts. 

When using the machine for TIG welding the TIG 
torch should be connected to the negative terminal 
and the work return to the positive terminal. 

MMA welding 

Insert the cable plug with electrode holder into the 
“+” socket on the front panel of the welding 
machine, and tighten it clockwise. Insert the cable 

plug of the work return lead into the “-”ve socket 
on the front panel of the welding machine, and 
tighten it clockwise. 

Select the MMA mode with the selector switch. 
Switch on the machine and adjust the MMA current 
control to the required current. Fix the electrode 
into the electrode holder and commence welding . 

OPERATION 

Before starting any welding activity ensure that 
you have suitable eye protection and protective 
clothing. Also take the necessary steps to protect 
any persons within the area. 

MMA welding current guide 

 

 

 

 

 

 

 

 

 

MIG / MAG Welding 
Insert the welding torch into the torch connector 
on the wire feed unit and tighten it. 
Install the wire spool on the spindle adapter of the 
wire feed unit. 
Connect the cylinder equipped with the gas 
regulator to the gas inlet of the interconnection 
cable set. Insert the cable plug with work clamp 
into the “-” output terminal on the front panel of 
the welding power source, and tighten clockwise. 
Insert the quick plug of the interconnection 
cable set into the “+”output terminal of the 
welding machine, and tighten it clockwise. Connect 
the other end  to the connection on the rear of the 
wire feed unit. Insert the multi pin plug of the 
interconnection cable set into the control cable 

Electrode Diameter 

(mm)  

Recommended Welding Current 

(A) 

1.0  

20~60 

1.6  

44~84

 

2.0  

60~100 

2.5  

80~120 

3.2  

108~148 

4.0  

140~180 

Summary of Contents for MIG 270 Separate

Page 1: ...A WILKINSON STAR PRODUCT 10 17 ISSUE 3 ...

Page 2: ...T 10 17 ISSUE 3 Contents Section Title Page 1 Your new product 3 2 Safety 4 3 Product overview 6 4 Panel layouts 7 5 Unpacking 9 6 Input and output connections 9 7 Maintenance and troubleshooting 10 8 Technical Parameters 11 ...

Page 3: ...tails from your product as these will be required for warranty purposes and to ensure you get the correct information should you require assistance or spare parts Date purchased ________________________________________ From where ________________________________________ Serial Number ________________________________________ The serial number will normally be located on the equipment data plate on ...

Page 4: ... wrap cables over your body Ensure that you take additional safety precautions when you are welding in electrically hazardous conditions such as damp environments wearing wet clothing and metal structures Try to avoid welding in cramped or restricted positions Ensure that the equipment is well maintained Repair or replace damaged or defective parts immediately Carry out any regular maintenance in ...

Page 5: ...ading and feeding wire during set up and operation When feeding wire be careful to avoid pointing it at other people or toward your body Always ensure machine covers and protective devices are in operation Precautions against fire and explosion Avoid causing fires due to sparks and hot waste or molten metal Ensure that appropriate fire safety devices are available near the cutting welding area Rem...

Page 6: ...ing facility Handling of Compressed gas cylinders and regulators All cylinders and pressure regulators used in welding operations should be handled with care Never allow the electrode electrode holder or any other electrically hot parts to touch a cylinder Keep your head and face away from the cylinder valve outlet when opening the cylinder valve Always secure the cylinder safely Never deface or a...

Page 7: ...r vent 6 Output terminal To connect the Interconnection cable 7 Control cable connector 8 Output terminal To connect the work clamp 9 2T 4T Selector 10 Gas purge Weld selector 11 Inductance control 12 Crater voltage control 13 Digital voltmeter 14 Mains indicator and Over heat indicator Rear view 15 Input cable gland 16 Air vent 17 Auxiliary socket for water cooler unit 18 Mains switch ...

Page 8: ...utton 21 Torch connector 22 Water connections 23 Voltage control Wire Feed unit Right side view 1 Shield gas connection 2 Torch holder 3 Control Cable 4 Water connection 5 Water connection 6 Welding cable connection 7 Welding wire spool cover 8 Interconnection cable Left side view 9 Wire feed assembly ...

Page 9: ...ositive terminal MMA welding Insert the cable plug with electrode holder into the socket on the front panel of the welding machine and tighten it clockwise Insert the cable plug of the work return lead into the ve socket on the front panel of the welding machine and tighten it clockwise Select the MMA mode with the selector switch Switch on the machine and adjust the MMA current control to the req...

Page 10: ... The owner of the equipment is required to return the equipment to a suitable recycling facility or to Starparts for the correct recycling of the product 7 MAINTENANCE AND TROUBLESHOOTING The following operation requires sufficient professional knowledge on electric aspects and comprehensive safety knowledge Make sure the input cable of the machine is disconnected from the electricity supply and w...

Page 11: ...re opening the case MODEL MIG 270 MIG 350 MIG 450 Input Voltage 1ph 230V 50 60Hz 3ph 400V 50 60Hz Ieff A MIG MMA 28 9 28 9 13 2 13 2 27 25 Input Power kVA MIG MMA 12 1 12 1 15 15 18 7 19 4 Output Voltage Range V 11 29 15 36 15 40 Output Current A MIG MMA 30 270 20 250 50 350 20 350 60 450 30 400 No Load Voltage V 54 65 62 Wire feed speed range 0 16m min 0 18m min 1 18m min Duty Cycle MIG 270 30 MM...

Page 12: ...A WILKINSON STAR PRODUCT 10 17 ISSUE 3 MIG MAG Series MIG 270 Order code ZXJM 272 MIG 350 Order code ZXJM 352 MIG 450 Order code ZXJM 452 Wilkinson Star Limited ...