background image

8

Overcurrent/overvoltage/overheating protection circuit is installed in this machine. When the mains
voltage,  output  current  or  inner  temperature  exceeds  the  set  standard,  the  machine  will  stop
automatically.  However,  excessive  use  (e.g.  too  high  voltage)  of  machine  may  also  damage  the
machine, so please note:

This cutting machine can create powerful cutting current and has strict cooling requirements that
cannot be met with natural ventilation. Therefore the built-in fan is very important in enabling the
machine to work stable with effective cooling. The operator should make sure that the louvers be
uncovered  and  unblocked.  The  minimum  distance  between  the  machine  and  nearby  objects
should be 25cm.

This machine is of automatic mains voltage compensation, which ensures that the cutting current
varies within the given range. In case that the input mains voltage exceeds the tolerance value,
it would possibly damage the machine. The operator should understand this circumstance fully
and adopt relevant precautions.

Remember  to  observe  the  max  load  current  at  any  moment  (refer  to  the  corresponding  duty
cycle). Make sure that the cutting current should not exceed the maximum load current. Overload
could obviously shorten the machine's lifespan, or even damage the machine.

A  sudden  halt  may  occur  with  the  yellow  LED  on  the  front  panel  on  while  the  machine  is  of
over-load status. Under this circumstance, it is unnecessary to restart the machine. Keep the
built-in fan working to lower the temperature inside the machine. Cutting can be continued after
the inner temperature falls into the standard range and the yellow LED is off.

Summary of Contents for L20701

Page 1: ...T MODEL CUT40 L20701 CU 0 L208 OPERATOR S MANUAL 3 INVERTER CUTTER...

Page 2: ......

Page 3: ...rding to relevant national Thank you for JASIC inverter cutter In order to ensure your safety and correct operation please read this manual carefully before operation Keep this manual properly for fut...

Page 4: ...als to avoid a fire Make ensure there are no inflammables near the cutting position to avoid a fire Beware of explosion Do not install the machine in an environment with explosive gas to avoid an expl...

Page 5: ...tion to fire safety cutting Ensure there is fire extinguisher nearby and make sure someone has been trained to operate the fire extinguisher Do not weld closed container Do not use this machine for pi...

Page 6: ...System characteristics 5 2 INSTALLATION AND CONNECTION 6 2 1 Installation requirements 6 2 2 Precautions 7 3 OPERATION 9 3 1 Panel functions of L20701 9 3 2 10 Notes for cutting operation 11 3 5 Cutti...

Page 7: ...08 6 4 40 96 25 300 20 40 HF 10 0 3 0 5 F IP21S 85 0 70 Arc ignition ode m Post flow time S Gas pressure range Mpa Enclosure ingress protection Air cooling 4 6 30 92 5 325 20 30 Non HF 10 0 3 0 5 B IP...

Page 8: ...d weight Table 1 2 Overall size and weight of the machine Figure 1 2 Appearance and size of the machine Unit mm Weight Kg Model Overall size L W H CUT40 L20701 CUT 0 L208 415 155 315 460 160 320 10 3...

Page 9: ...mark Material code Cutting torch Earth clamp Operator s manual CUT series Standard configuration Standard configuration Standard configuration Standard configuration 1 1 1 1 Table 1 4 Configuration of...

Page 10: ...ng power supply inverter technology greatly reducing the volume and weight of the cutter and obviously enhancing the conversion efficiency by 30 Features of CUT series Economic and practical by adopti...

Page 11: ...he normal work time of the machine under rated maximum current holding in the period when taking 10 minutes as a period The rated duty cycle of this machine is 40 60 Using the cutting machine continuo...

Page 12: ...ut cable Connection of cutting torch Connect the copper nut on the cutting torch to the gas electric connector on the front panel of the machine and tighten it clockwise to avoid gas leakage Insert th...

Page 13: ...n of the reducer valve Steps for reducer setting are as follows start the gas flow lift the pressure control knob upward adjust the gas pressure to the desired value by rotating the knob rotate to dir...

Page 14: ...is of automatic mains voltage compensation which ensures that the cutting current varies within the given range In case that the input mains voltage exceeds the tolerance value it would possibly damag...

Page 15: ...of the machine 1 2 3 4 No Part name Function Overcurrent in dicator To indicate the machine is under ov ercurrent protection status when it illuminates 5 6 7 The power ight To indicate the machine wo...

Page 16: ...work properly Plastic shutter As the exit for air duct for ventilation and heat dissipation Current control knob To adjust the output current value output terminal To connect the earth clamp 1 2 3 No...

Page 17: ...initiate the cutting from the edge of workpiece unless penetration is needed Ensure spatters fly from the bottom of workpiece while cutting If spatters fly from the top of workpiece it indicates that...

Page 18: ...t proper current according to the cutting parameters table workpiece material cutting thickness and cutting speed etc The figure in the below table is an approximation Table 3 1 Cutting speed in when...

Page 19: ...l be strong arc in the nozzle which will break down the electrode and the nozzle or even burn the torch Nozzles of different models are different so ensure the nozzle is of the same model when replaci...

Page 20: ...ning Earth cable Cutting cable Whether the grounding wires including workpiece GND wire and cutting machine GND wire break off Whether the insulating layer of the cable is worn or the conductive part...

Page 21: ...uncovering the cutting machine When the machine is powered on keep hands hair and tools away from the moving parts such as the fan to avoid personal injury or machine damage Avoid rain water and vapor...

Page 22: ...he machine the power indicator illuminates and the fan works When pressing the control button of the cutting torch the solenoid valve inside the machine functions but there is no HF discharge rustling...

Page 23: ......

Page 24: ...SHENZHEN JASIC TECHNOLOGY CO LTD No 3 Qinglan 1st Road Pingshan District Shenzhen Guangdong China www jasictech com...