INSTALLATION INSTRUCTIONS

IMPORTANT: ALWAYS TURN THE POWER OFF IN ACCOR-
DANCE WITH OSHA’S LOCKOUT/TAGOUT PROCEDURES
(29 CFR 1910.147) BEFORE PERFORMING ANY MAINTE-
NANCE OR REPAIRS.

1 Mount the Model AST--100 tester securely on a bench

or table top in the vicinity of where the Model

AN--10K1 Stunner is being used and/or maintained.

Be sure to mount the safety plate (item 9) between the

Model AST-100 and the bench.

1.1 Use the four (5/16) clearance holes to secure the

housing and safety plate.

1.2 Make sure that the top of the housing is at a conve-

nient height to facilitate insertion and extraction

of the AN--10K1 Stunner.

2 Mount the control box in the vicinity of the tester

housing. Two cords, two meters long with connectors

are provided.

3 The power requirement for the tester is 10 Watts at

120VAC, 60 Hz or 220VAC, 50 Hz.

4 Connect the control box to the proximity switches

(item 8) using the two cables (item 10) provided with

the control box.

4.1 The top and bottom cables are clearly identified

(top or bottom) with cable ties (item 11) and must

be connected to the appropriate (top or bottom)

connector.

OPERATION INSTRUCTIONS

Note: Operator’s head must be a safe distance away

and on one side of the AN-10K1 Stunner when the

stunner is in use to avoid injury from the tool’s recoil.

Note: It is not necessary to test the AN--10K1 Stunner be-

fore every use, but the tool should be checked at least

once per shift to ensure effectiveness of the stunner.

1 Turn power switch (item 27) on.

2 Verify that the pressure regulator for the air supply to

the AN--10K1 Stunner is set for 150--175 psi.

3 Place the AN--10K1 Stunner into the tester.

3.1 Be careful to align the slot in the top of the tester

housing with the ear on the trigger contact bushing

of the AN--10K1 Stunner.

4 After the AN--10K1 Stunner is resting in the tester

housing, hold the tool firmly to reduce and contain the

recoil.

5 For Current Comtrol Box (Figure B): squeeze the trig-

ger once to obtain reading.

For Original Comtrol Box (Figure C): squeeze the

trigger once to prime the timer, and then squeeze the

trigger a second time to obtain a reading.

6 The display will read directly in microseconds the

time it takes for the stunning rod to pass by both prox-

imity switches. A reading of 2250 equals 0.00225 sec-

onds.

6.1 A reading below 2250 indicates an acceptable

stunning speed. A reading above 2500 indicates

a repair is necessary.

MAINTENANCE INSTRUCTIONS

ALWAYS TURN THE POWER OFF IN ACCORDANCE WITH
OSHA’S LOCKOUT/TAGOUT PROCEDURES (29 CFR
1910.147) BEFORE PERFORMING ANY MAINTENANCE OR
REPAIRS.

1 DAILY:

1.1 Check that the proximity switches (item 8) are se-

curely attached to the tester housing.

1.2 Check that the two cables from the control box are

securely attached to the proximity switches in the

tester housing.

2 REPLACING THE PROXIMITY SWITCHES:

2.1 Remove the cable from the control box.

2.2 Loosen the locking nut on the proximity switch

(item 8) and unthread the switch from the tester

housing.

2.3 Thread the new switch into the tester housing.

2.4 Locate the front end of the switch 1/16th inch re-

cessed from the inside diameter of the guide (item

2).

The end of the switch must not protrude into

the guide bore

.

2.5 Tighten the locking nut after the switch has been

properly located.

3 REPLACING THE GUIDE:

3.1 Remove the proximity switches (item 8) as de-

scribed in section 2.

3.2 Remove three socket head cap screws (item 1).

3.3 Push guide out from top of tester housing.

3.4 To reassemble, reverse steps 3.1 to 3.3.

3.4.1 Use

Loctite 262

on the three socket head cap

screws (item 1).

Summary of Contents for AST-100 Series

Page 1: ...tenance and Cleanup Personnel 3 Parts Diagram and List 4 Operation Diagram 7 Installation Instructions 8 Operation Instructions 8 Maintenance Instructions 8 PRODUCTS CORPORATION 33 ANDERSON ROAD MIDDLETOWN CONNECTICUT 06457 4926 UNITED STATES OF AMERICA TEL 860 347 7271 FAX 860 347 6978 6216002 Model AST 100 STUNNER TESTER EQUIPMENT SELECTION Ordering No Preliminary ...

Page 2: ... board give one copy to the operator s give one copy to the maintenance foreman and give one copy to the sub contract cleanup internal cleanup fore man Additional copies will be provided upon request 5 The AN 10K1 Stunner is designed and intended to be powerful This fact should be obvious to your employees but you must emphasize it to them 6 Ensure eye and ear protection is worn at all times when ...

Page 3: ... s lockout tagout procedures 29 CFR 1910 147 before performing any cleanup 3 Never put fingers hands or other parts of the body directly in front of the AN 10K1 Stunner 4 Always wear eye and ear protection when operating the tester 5 Always keep operator s head a safe distance away and off to one side of the stunner when using the tester to avoid injury from the stunner s recoil 6 Always keep all ...

Page 4: ...OF AMERICA TEL 860 347 7271 FAX 860 347 6978 6216002 ITEM PART NO PART NAME QTY 1 1055746 Socket Head Cap Screw 6 2 1058186 Guide 1 3 1016650 Housing 1 4 1017390 Nameplate Label 1 5 1055274 Drive Screw 6 6 1032646 Wear Plate 1 7 1017400 Name and Info Label 1 8 1005156 Proximity Switch 2 9 1032702 Safety Plate 1 AST 100 Stunner Tester Figure A ...

Page 5: ...el Gr 2 19 1055010 Pan Head Screw 2 20 1004022 Internal Lock Washer 2 21 1060100 Threaded Insert 2 22 1063494 Terminal Block Grey 5 4 23 1063363 Terminal Marker 14 ITEM PART NO PART NAME QTY Electric Control Box Current Configuration Figure B ITEM PART NO PART NAME QTY 24 1072070 Timer 1 25 1061512 Wire Ferrules 5 2 26 1017384 On Off Label 1 27 1005174 Electric Switch 1 28 1063456 Terminal Marker ...

Page 6: ...nector 6 ckt 1 35 1063968 Crimp Terminal 5 36 1063969 Power Supply 1 37 1055482 Pan Head Screw 4 38 1004006 Internal Lock Washer 8 39 1061475 Hex Spacer 4 ITEM PART NO PART NAME QTY ITEM PART NO PART NAME QTY 40 1063970 Electrical Connector 3 ckt 1 41 1063971 Female Terminal Disconnect 1 42 1063822 Terminal Block Base 5 43 1063490 Diode 2 44 1063972 Terminal Bridge 5 45 1063823 Terminal Block Plug...

Page 7: ...operation diagram Model AST 100 page 7 of 8 6 JARVIS PRODUCTS CORPORATION 33 ANDERSON ROAD MIDDLETOWN CONNECTICUT 06457 4926 UNITED STATES OF AMERICA TEL 860 347 7271 FAX 860 347 6978 6216002 ...

Page 8: ...tunner is set for 150 175 psi 3 Place the AN 10K1 Stunner into the tester 3 1 Be careful to align the slot in the top of the tester housingwiththeearonthetriggercontactbushing of the AN 10K1 Stunner 4 After the AN 10K1 Stunner is resting in the tester housing hold the tool firmly to reduce and contain the recoil 5 For Current Comtrol Box Figure B squeeze the trig ger once to obtain reading For Ori...

Reviews: