4) 

It is important to lower the ventilation door at the front so that heat can spread out 
in the room. The appliance will become much hotter without the circulation of air 
coming  from  the  fans;  thus  the  ceilings,  the  walls  and  everything  around  the 
appliance will be exposed to an higher heat than usual. 

 
 
 
 
 
 

 
 
 
 
5) 

As soon as the electrical failure ends, replace the air entry rod at its first position 
(step 1) et keep the handle upwards in order to have an opened air entry (step 3). 
Then, close the door of the appliance.. 

 
 
 

AIR SUPPLY

 

 

A new air supply can be done by the following ways: 
 

Indirect method :

  

In  the  case  of  an  appliance  not  certified  for  a  direct 
connection  with  a  source  of  new  air  supply,  the  new  air  is 
brought in a conduit at a maximum of 300mm (12 Po) of the 
appliance, in order to not compromise its operation. 

 

Mechanical ventilation :

   If the home is built with a ventilation system (air exchange or 

heat recovery) 

 

I.  The  ventilation  system  might  be  able  to  supply  an  efficient 

air quantity to a solid combustible appliance, and 

 

II.  The  owner  should  be  informed  that  the  ventilation  system 

may  have  to  be  rebalanced  by  a  technician  specialized  in 
ventilation  after  the  installation  of  the  solid  combustible 
appliance.. 

 

 

Summary of Contents for ATFM

Page 1: ...490 rue de l Argon Qu bec Qu bec G2N 2C9 Phone 418 849 8095 Fax 418 849 0077 www jaroby com September 7th 2007 Review ATFM Certified and tested according to CAN CSA B366 1 M91 norms...

Page 2: ...VERTICAL INSTALLATION 11 CLEARANCES 12 INSTALLATION OF THE FIREBRICKS 13 FANS AND THERMODISC 14 INSTALLATION OF THE 460 CFM FAN AND THE PROTECTION BOX 15 PROPULSION MODE 15 INSTALLATION OF THE 2 EXIT...

Page 3: ...QUALIFY CERTIFIED TECHNICIAN AND IN CONFORMITY WITH THE OWNER S MANUAL GUIDE GIVEN WITH THIS APPLIANCE THE INSTALLATION MUST BE IN AGREEMENT WITH LOCAL AND NATIONAL REGULATIONS APPLICABLE FOR SOLID F...

Page 4: ...4cm Dimensions Exterior height 42 in 107 95cm Exterior width 27 in 69 85cm Exterior depth 38 in 97 79cm Door openning 16 in X 10 in 40 64cm X 26 67cm Inside height 12 in 30 48cm Inside width 19 in 48...

Page 5: ...a minimum of 64 ft2 and must be very well ventilated Minimum clearances found in this manual must be observed Never use a non isolated exterior conduct or a single wall flue pipe as an exterior exit P...

Page 6: ...e knowledge of the procedure to be followed in case of a chimney fire Think of an emergency plan In case of a chimney fire Hermetically close the doors and the air intakes Water the combustible materi...

Page 7: ...light smoke is released from the paint during the first hours of use Even if this nuisance is temporary open the windows and the doors in order to ensure a good ventilation This special paint is conce...

Page 8: ...oss with an insulated lining The chimney has to be installed with a stainless steel lining Make sure that all smoke pipe joints are really airtight A leak reduces the efficiency of the appliance and c...

Page 9: ...cal laws or the CAN CSA B365 ULC S635 ULC S640 UL 1777 norms Install the chimney following the manufacturer s instructions EXTERIOR VERTICAL INSTALLATION The ATFM wood appliance must be installed in a...

Page 10: ...applicable local laws or the CAN CSA B365 norm Install the chimney following the manufacturer s instructions CROSS STYLE INSTALLATION The ATFM wood appliance must be installed in accordance with the...

Page 11: ...11 VERTICAL INSTALLATION The ATFM wood appliance must be installed in accordance with the applicable local laws or the CAN CSA B365 norm Install the chimney following the manufacturer s instructions...

Page 12: ...complete your decoration by its originality and its heat This appliance only needs a 12 inches clearance at its back and 12 inches from the lateral walls For the heat exchanger the clearances of zero...

Page 13: ...install the side wall bricks 3 Install the back ones 4 Then install three pipes 2 and 3 and fix them 5 Install the two plates retaining the wool 6 Slide the bricks to be placed under the wool and to...

Page 14: ...he fans When the appliance is in fonction and that the protection thermodisc fixed on the ventilation conduct reaches a temperature of 1600 F the thermodisc will stop the fans and will close the air e...

Page 15: ...al box on the side 2 screws Position the rod allowing the air intake into the hole 2 Remove the panel recovering the two square holes Fix the 460CFM fan on the appliance with the 4 bolts rings and nut...

Page 16: ...connector and let it exceed of 6 inches in the protection box Tighten the connector screw Connect the wires Position and fix the left and right sides of the 460CFM fan box Use 7 screws for each sides...

Page 17: ...s Fix the two pipes of 6 inches diameter by using 2 screws per pipe Do not block the anti repression valves operation Fix the thermocouple box L 160 at 30 76cm Plan the thermodisc hole before fixing t...

Page 18: ...screws Install the retaining collar with 2 bolts and nuts 1 4 X 2 and then tighten the end on the simple pipe Fix it all with 6 screws Screw the fan grid GV460 by using 5 bolts 1 X with locks Screw t...

Page 19: ...6 inches diameter coated sheet pipe or black steel Fix the 90 degrees elbow only with screws of less than of length because it could affect the good operation of the anti repression valve Fix the ther...

Page 20: ...20...

Page 21: ...ommendations you are ready for the lighting 1 Place papers and small wood in the appliance 2 Before lighting be sure that the chimney is warm enough 3 When the fire is well lit gradually add bigger wo...

Page 22: ...l a smoke return a bad combustion and a counter blow even though you have a combustion or not b Your other appliances such as hearths or other heating appliances release odors heat badly provoke smoke...

Page 23: ...ing instructions and images 1 Lift up the air entry rod 2 Hook the rod onto the support in order to allow an air supply 3 To measure out the quantity of air into the combustion chamber you have to rot...

Page 24: ...ance AIR SUPPLY A new air supply can be done by the following ways Indirect method In the case of an appliance not certified for a direct connection with a source of new air supply the new air is brou...

Page 25: ...hey must always be in good condition Do not alter or modify the air intakes of the appliance in order to get a stronger fire To clean the glasses J A Roby Inc recommends using products sold for this p...

Page 26: ...TS LIST BRICK PIPES GLASSES BRICKS SUPPORTS DOOR HANDLE APPLIANCE DOOR FAN SEALING CORDS THERMODISC DAMPER MOTOR TRANSFORMATOR THERMOSTAT BUTTERFLY VALVE AIR ENTRY ROD TO ORDER PARTS PLEASE CONTACT YO...

Page 27: ...by inc will NOT accept any transportation charges The 2nd year J A ROBY Inc assume 50 of repairs according to the above conditions The 3rd year J A ROBY Inc assume 45 of repairs according to the above...

Reviews: