24
4)
It is important to lower the ventilation door at the front so that heat can spread out
in the room. The appliance will become much hotter without the circulation of air
coming from the fans; thus the ceilings, the walls and everything around the
appliance will be exposed to an higher heat than usual.
5)
As soon as the electrical failure ends, replace the air entry rod at its first position
(step 1) et keep the handle upwards in order to have an opened air entry (step 3).
Then, close the door of the appliance..
AIR SUPPLY
A new air supply can be done by the following ways:
Indirect method :
In the case of an appliance not certified for a direct
connection with a source of new air supply, the new air is
brought in a conduit at a maximum of 300mm (12 Po) of the
appliance, in order to not compromise its operation.
Mechanical ventilation :
If the home is built with a ventilation system (air exchange or
heat recovery)
I. The ventilation system might be able to supply an efficient
air quantity to a solid combustible appliance, and
II. The owner should be informed that the ventilation system
may have to be rebalanced by a technician specialized in
ventilation after the installation of the solid combustible
appliance..