background image

SPIDER W40 – Power supply for 2 controllers with battery support 

 

 

 

 

5/2014 

Black line 

www.codeks.eu 

 

CONNECTOR DEV2 – connection for controller and el. strike 

or other controlled device 

Contact 

Description   Specification 

1  

12V  

Max. 0.3 A. Connect 12V DC to 

controller, el. strike, other device 

(siren...). 

2  

GND 

Ground. Connect ground to 

controller. 

3  

LOCK  

Input for el. strike (also controls 2. 

relay). Connect ground to el. strike 

and O0 from controller. 

4  

TMP 

Input for alarm. Connect ground 

from other device (siren...) and O1 

from controller (with alarm output). 

SWITCH 

Input for door status switch. 

Connect magnet for door status 

and I0 from controller. 

6  

BUTTON 

Input for push button. Connect 
push button and I1 from controller. 

7  

CA 

Connect RS485 communication 
from controller. 

8  

CB 

Connect RS485 communication 

from controller. 

9  

OPEN 

Relay – open contact (NO) 

10  

MIDDLE 

Relay – middle contact 

 

CONNECTOR TMP – tamper/alarm shut down connection 

Contact 

Description  

Specification 

1  

ON 

ON switch - when connected to 

ground power supply turns back 

on from “OFF” state  

2  

GND 

Ground 

3  

OFF  

OFF switch – when connected to 

ground power supply turns off – 

used in connection with alarm 

output on REX V9 or with external 

tamper switch 

 

 

Environment 

Do not install the power supply on/in a place, where it can come in 

contact with water. You must assure good cable joints, protected 

against moisture, otherwise corrosion may damage the power 

supply. Damage in such cases is not covered by the warranty. You 
have to install the power supply in an airy place. 

 

Opening of the housing 

There are two holes on each side of the housing. Use an 

appropriate size screwdriver and push it in all four holes. When the 

lid pops out, gently remove it. Two black screws are supplied for 

additional fastening of the lid. 

 

Communication  

Ethernet: 

Connect the controllers to the computer through your LAN via 

Spider’s Ethernet interface. Adjust network settings of the Spider 

using the Codeks Device Manager software so that it will function 

properly in your network.

 

Please consult Codeks Device Manager’s 

manual. 

 

RS485: 

If the power supply does not have a built-in Ethernet interface, it 

only serves to power devices. Connect RS485 communication from 

controllers to one of the communication converter, from the Spider 

family: Spider W5-USB, Spider W5-NET, Spider W40+NET and 

through it to the computer.  

 
 
 
 
 

 

ORDERING CODES 

 

Spider W40 

Communication: 

NET 

– Ethernet connection 

 

Code 

Specification 

Spider W40 

30 W power supply for 2 controllers 

with battery support 

Spider W40-NET 

30 W power supply for 2 controllers 

with battery support, Integrated 

Ethernet 

 
 

OTHER 

 

Please read through our warranty and disclaimer statements. 

 

Connection scheme and additional support for the use of this 

product can be found on: 

http://www.jantar.si/forum/en

 

 
CONTACT:

 

Jantar d.o.o. 

Kranjska cesta 24 

4202 Naklo 

 

 

web: 

www.codeks.eu

 

SLOVENIA 

 

 

mail

[email protected] 

 

 

Reviews: