After  8. beep 
 

Press 8 and 

 

Sound is OFF 
Tamper is OFF 

Door status switch input- normally opened (NO) 
Time is set in minutes 

After  9. beep 

 

Press 9 and 

 

Sound is ON 

Tamper is OFF 
Door status switch input- normally opened (NO) 
Time is set in minutes 

After  10. beep 
 

Press 10 and 

 

Sound is OFF 
Tamper is ON 
Door status switch input- normally opened (NO) 
Time is set in minutes 

After  11. beep 
 

Press 11 and 

 

Sound is ON 
Tamper is ON 
Door status switch input- normally opened (NO) 
Time is set in minutes 

After  12. beep 
 

Press 12 and 

 

Sound is OFF 
Tamper is OFF 
Door status switch input- normally closed (NC) 
Time is set in minutes 

After  13. beep 
 

Press 13 and 

 

Sound is ON 
Tamper is OFF 
Door status switch input- normally closed (NC) 

Time is set in minutes 

After  14. beep 
 

Press 14 and 

 

Sound is OFF 
Tamper is ON 

Door status switch input- normally closed (NC) 
Time is set in minutes 

After  15. beep 
 

Press 15 and 

 

Sound is ON 
Tamper is ON 
Door status switch input- normally closed (NC) 
Time is set in minutes 

 
Function 16) Reset 

“HARD” reset. Use it instead off manual reset (power off/on). 

Reset with master card: 

Approach the master card and remove it after 16 double beeps. The 
controller will start to beep every second. Approach a user card after three 
beeps.  

Reset with master code: 

Enter the master code and press 

 

. Press 16 and 

 

. Press 3 and 

.

 

 
 

AS AN ACCESS CONTROLLER 
 

As an access controller, it is intended for controlling entries, exits and passes 
of users in the system and controlling sliding doors, ramp, el. strike, turning 
alarm on/off…  It needs to be set with JantarV7, BLOCKER or CODEKS 
software.  

 
The controller switches to access controller when tables are sent by 
the software or when it is set to mode 4 with function 9. Change the 
controller’s address from 255 to any number between 1 and 254. If 
you have more controllers on the communication line, don’t duplicate 
addresses.  

Add them one by one on the communication line, because every 
controller has address 255 by default. 

 

 
Communication  

Connect the controller to the computer, with one of the power supplies, with 
communication converter, from the Spider family: Spider W5-USB, Spider 
W5-NET, Spider W40+NET. 
 
The RS485 communication bus is used between the controllers and Jantar 

software. Up to 128 controllers can be lined up into one communication line. 
The maximum length of the communication line is 1000 cable meters. It is 
recommended that you use an FTP or S-FTP cable. Only a serial connection 
of controllers in a single communication line is allowed. 

Star (parallel) 

connection is not allowed

.  

 
All shields of S-FTP cables must be wired together and at 

one point

 

connected to the earth. Individual connections to the earth are not allowed. 
Do not connect the shield of the cable to the ground of the controller. 

 

In  the  event  of  problems  in  communication,  a  termination  resistor 
needs to be added. We recommend using 120 Ohm resistors on each 
side of the cable. Converters are, on the RS485 side, protected with 
slow-blow fuses and transient voltage suppressors.

 

 
 
 
 

Changing back to standalone controller from access controller: 

In the Codeks Device Manager software do the “Brainwash” of the 

controller. Address of the controller’s switches back to 255.  

 
 

ORDERING CODES 

 
REX

 [box]-[card]-[software]  

Box:  

K

 

Card:  

– reading frequency 125kHz (cards)  

– reading frequency 13.56MHz (cards)  

Software: 

9

 – BLOCKER, CODEKS (support for V7 min.7.995.6.1032) 

 

 

Code 

Description 

REX K-1-9 

Standalone or access controller in 

K

 box, Frequency 

125kHz, for JantarV7, BLOCKER or CODEKS software 

REX K-3-9 

Standalone or access controller in 

K

 box, Frequency 

13.56MHz, for JantarV7, BLOCKER or CODEKS software 

 
 

OTHER 

 
Warranty only applies when the controller Rex is used with power supply 
or/and communication converter from the Spider family. 
 
Please read through our warranty and disclaimer statements. 

 

Connection scheme and additional support for the use of this product can be 
found on: 

http://www.jantar.si/forum/en

 

 
CONTACT:

 

Jantar d.o.o. 
Kranjska cesta 24 
4202 Naklo 

 

 

web: 

www.jantar.si

 

SLOVENIA 

 

 

mail: 

[email protected] 

Summary of Contents for REX K-1-9

Page 1: ... a resistance of approximately 9 ohm per 100m The power supply at the end of cable should be a minimum of 9V If you are using el strike it is highly recommended that the voltage drop is calculated At greater distances a thicker cable of 0 5mm2 or more should be used wherever possible If the load is for example 0 5A with el strike then on the 0 22mm2 cable voltage drop will be 4 5V at 100m For the ...

Page 2: ...on 2 In the controller registered cards and codes are arranged in order of their registration Every registered card and code is saved to its own position If you save a new card or code to already taken position then the previous card or code will be deleted Register user card with master card Approach the master card and remove it after 1 double beep Within a period of three seconds approach a use...

Page 3: ...move it after 9 double beeps The controller will start to beep every second Each beep presents a different function which is selected with a user card Standalone controller Approach a user card before 1 beep Wiegand 26 bit reader Jantar Approach a user card after 1 beep The reader sends a card data at once and pressed buttons separately This is used in Jantar s systems so that the controller disti...

Page 4: ...m one by one on the communication line because every controller has address 255 by default Communication Connect the controller to the computer with one of the power supplies with communication converter from the Spider family Spider W5 USB Spider W5 NET Spider W40 NET The RS485 communication bus is used between the controllers and Jantar software Up to 128 controllers can be lined up into one com...

Reviews: