Jantar POPULUS A-1-NET Quick Start Manual Download Page 2

POPULUS A-1-NET and POPULUS A-3-NET – Access controller  

 

 

 

 

4/2015 

Black line 

www.jantar.si 

 

INSTALLATION 

A special holder, provided with the controller, is needed for 

attachment to the wall. Two screws are enclosed in the box. After 
the holder has been affixed, put the controller onto the holder and 

press – after you hear the click, it is fixed. If you want to remove 

the controller from the wall, put the screwdriver under the 

controller’s casing (as close as possible to the holder’s attachment 

points) and turn it gently. 

 

Installation holder for A box. 

 

 

 

COMMUNICATION  

Ethernet: 

Connect the controller to the computer through your LAN via 

Ethernet connector. Use at least UTP CAT 5e cable. Adjust network 

settings of the controller using the Codeks Device Manager 

software so that it will function properly in your network.

 

Please 

consult Codeks Device Manager’s manual. 

 

RS485: 

Connect the controller to the computer, with one of the power 

supplies, with communication converter, from the Spider family: 

Spider W5-USB, Spider W5-NET, Spider W40+NET.  

 

The RS485 communication bus is used between the controllers and 

Jantar software. Up to 128 controllers can be lined up into one 

communication line. The maximum length of the communication 

line is 1000 cable meters. It is recommended that you use an FTP 

or S-FTP cable. Only a serial connection of controllers in a single 

communication line is allowed. 

Star (parallel) connection is not 

allowed

.  

All shields of S-FTP cables must be wired together and at 

one 

point

 connected to the earth. Individual connections to the earth 

are not allowed. Do not connect the shield of the cable to the 

ground of the controller. 

 

In  the  event  of  problems  in  communication,  a  termination 

resistor needs to be added. We recommend using 120 Ohm 

resistors  on  each  side  of  the  cable.  Converters  are,  on  the 

RS485  side,  protected  with  slow-blow  fuses  and  transient 

voltage suppressors.

 

 
 

ACCESS CONTROLLER 

As an access controller, it is intended for controlling entries, exits 

and passes of users in the system and controlling sliding doors, 

ramp, el. strike, turning alarm on/off…  It needs to be set with 
CODEKS software.  

 

The default address of the controller is the same as the last 

digit of the IP address. E.g. if the IP address of the 
controller is 192.168.110.105, then the controller's address 

is 105. 

 

Reset to the factory settings (brainwash): 

When the controller is reset to the factory settings (brainwash), the 

controller address is set to 255.

 

 
 

 
 
 
 
 
 
 
 

 
ORDERING CODES 

Populus 

[box]-[card]-[software]

 

Box:

        A

 

Card:

       1 

- 125kHz reading frequency (cards)

 

  3 

- reading frequency 13.56MHz (cards)  

Communication: 

NET 

– Ethernet connection 

 

Code 

Specification 

POPULUS A-1-NET 

Access controller in 

A

 box,

 

outputs, 1 reader, Frequency 

125kHz, Integrated Ethernet, for 

CODEKS  

POPULUS A-3-NET 

Access controller in 

A

 box,

 

outputs, 1 reader, Frequency 
13.56MHz, Integrated Ethernet, for 

CODEKS  

 

 

OTHER 

Please read through our warranty and disclaimer statements. 

 

Connection scheme and additional support for the use of this 

product can be found on: 

http://www.jantar.si/forum/en

 

 