8
PRESSER BAR HEIGHT AND ALIGNMENT
Correct setting
When presser foot lifter is up position, the distance between the bottom surface of the foot
and needle plate should be 6.0mm.
To adjust
1. Remove the face plate. (See page 3.)
2. Remove set screw A and remove lamp holder set plate.
3. Raise the presser foot and loose the presser bar bracket screw and adjust the height
(6.0mm).
4.
Check if the presser foot is parallel to the openings for the feed dog on the needle
plate. If not, adjust it.
5. Tighten the presser bar bracket screw while holding the presser bar to keep the foot
parallel to the openings.
6. Attach the lamp holder set plate.
7. Attach the face plate.
Summary of Contents for JF1018S
Page 1: ...SERVICING MANUAL Model JF1018S...
Page 24: ...22 WIRING...