16
8. Clearance between the Needle and
Looper
The clearance between the tip of the looper and scarf of
the attached needle (Schmetz ELx705, size 80/12)
should be 0 to 0.05 mm.
z
Remove the free arm cover (see page 4) and
needle plate.
x
Turn the handwheel toward you until the looper
point
q
comes behind the needle.
c
Loosen the setscrews
w
and thrust the front needle
guard
e
against the needle to make 0 to 0.05 mm
clearance between the needle and tip of the looper.
v
Tighten the setscrews
w
and check the clearance.
b
Attach the free arm cover and needle plate.
q
w
e
e
0 to 0.05 mm