20
NEEDLE POSITION MISALIGNMENT
IF THE NEEDLE BAR MOVES SIDEWISE (ZIGZAG) WHEN THE PATTERN “ “ IS SELECTED AND THE
ZIGZAG WIDTH IS SET AT “ 0 “, ADJUST AS FOLLOWS:
ADJUSTMENT PROCEDURE:
1. SET THE PATTERN SELECTOR DIAL AT “ “, ZIGZAG WIDTH DIAL AT “ 0 “ AND REMOVE THE
FRONT COVER (SEE PAGE 7).
2. LOOSEN THE SETSCREW (A) AND GENTLY PUSH DOWN THE ZIGZAG ROD (C) TO THE BOTTOM OF
THE SLOT ON ZIGZAG REGULATOR ARM (B).
3. TIGHTEN THE SETSCREW (A), SWING THE ZIGZAG WIDTH REGULATOR ARM (B) AS SHOWN BY THE
ARROW
TO CHECK IF THE NEEDLE BAR DOES NOT MOVE SIDEWISE.
IF THE NEEDLE BAR STIL MOVES, LOOSEN THE SETSCREW (A) AND MOVE THE ZIGZAG WIDTH
ADJUSTING PLATE (D) UNTIL THE NEEDLE BAR STOPS MOVING SIDEWISE WHEN SWINGING THE
ZIGZAG WITH REGULATOR ARM.
4. ATTACH THE FRONT COVER.
MECHANICAL ADJUSTMENT
SETSCREW (A)
ZIGZAG WIDTH ADJUSTING
PLATE (D)
ZIGZAG WIDTH ROD (C)
ZIGZAG WIDTH REGULATOR
ARM (B)
www.promelectroavtomat.ru