8
6.0 mm
MECHANICAL ADJUSTMENT
PRESSER BAR HEIGHT
The distance between the bottom of the presser foot in up position and the needle plate should be 6.0 mm.
TO REMOVE:
1. Remove the face cover (see page 4) and needle.
2. Lower the feed dog below the needle plate. Place a block 6 mm thick under the presser foot and
lower the presser foot lifter (A).
3. Loosen the hexagonal socket screw (B). Raise the presser foot lifter and tighten the setscrew (B)
firmly.
TO ATTACH:
4. Attach the needle and face cover.
NOTE:
Make sure that the presser foot should be parallel to the feed dog slot in the needle plate.
Presser foot should be parallel to
the feed dog slot.
(A)
(B)