5.9 

Set Temperature Menu 

MENU > SET TEMP > POOL or SPA > SET TEMP VALUE

The SET TEMP menu allows you to preset the pool 

and spa thermostats. 

NOTE

  For  pool/spa  combination  systems,  the  default 

pool  temperature  is  80°F  and  the  default  spa 

temperature  is  102°F.  For  pool  only/spa  only 

systems, the default TEMP1 temperature is 80°F 

and the default TEMP2 temperature is 60°F.

To set the Time 

Highlight  MENU  and  press  SELECT,  highlight 

SET TIME and press SELECT. Use the UP/DOWN 

arrow keys to set values. Press the SELECT button 

to continue.

5.11  AquaPure Menu

MENU > SET AQUAPURE > SET OUTPUT%

NOTE

  This equipment may not be part of your system. 

Please check with your installer.

AquaPure  Chlorine  Generator  system  exclusively 

communicates with the AquaLink RS. The AquaPalm 

Handheld  Remote  will  display  %  of  chlorine 

output.
This menu item will only appear when an AquaPure 

chlorine generator is connected to the AquaLink RS 

system by means of the red 4-pin terminal bar.

To set the AquaPure Output Percentage (%)

Highlight MENU and press SELECT, highlight SET 

AQUAPURE and press SELECT. Use the UP/DOWN 

arrow keys to change the percentage.
See Section 5.14 for BOOST options.

NOTE

  When the Chlorine Generator output percentage 

is  set  to  a  value  greater  than  0  and  the  filter 

pump is on, the system salinity level and output 

percentage  appears  on  the  equipment  status 

screen.

SET TIME

10/10/05 MON

10:00 AM

Use ARROW KEYS

to set value.

Press SELECT

to continue.

1

2

select

back

MAIN MENU

SET  TEMP

SET  TIME

PALM OPTIONS

1

2

select

back

Aqu

a

P

a

l

Aqu

a

P

a

l

Figure 21.  Set Time Menu

1

2

select

back

MAIN MENU

SET  TEMP

SET  TIME

PALM OPTIONS

1

2

select

back

SET TEMP

POOL HEAT      80°F

SPA HEAT       104°F

Highlight an 

item and press 

SELECT

1

2

select

back

SET TEMP

POOL HEAT      80°F

SPA HEAT       104°F

Highlight an 

item and press 

SELECT

1

2

select

back

SET TEMP

POOL HEAT      85°F

SPA HEAT       104°F

Highlight an 

item and press 

SELECT

Aqu

a

P

a

l

Aqu

a

P

a

l

Aqu

a

P

a

l

Aqu

a

P

a

l

Figure 20.  Set Temperature Menu

To set Pool/Spa Temperatures 

Highlight MENU and press SELECT, highlight 

SET TEMP and press SELECT. Inside the SET 

TEMP menu, use the UP/DOWN arrow keys to 

highlight either POOL (TEMP1) or SPA (TEMP2) 

and press SELECT. Use the UP/DOWN arrow keys 

to increase or decrease the temperature and press 

SELECT to apply the setting.

5.10  Set Time Menu 

MENU > SET TIME

The SET TIME menu allows the correct time and date 

to be entered. The correct time and date ensures that 

programming will work properly. 

NOTE

  A nine volt (9 V) battery is located at the Power 

Center that allows the system clock to continue to 

run during power outages. Ensure that the battery 
is checked or replaced annually.

Summary of Contents for AquaPalm

Page 1: ...hese limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not ins...

Page 2: ......

Page 3: ...h 10 Section 5 AquaPalm Handheld Remote Menus 10 5 1 Pool Mode Spa Mode 10 5 2 Equipment On Off Menu 10 5 3 Filter Pump Pool Mode 11 5 4 Spa 11 5 5 Pool Heat 12 5 6 Spa Heat 12 5 7 Solar Heat 13 5 8 A...

Page 4: ...regnant or possibly pregnant women should limit spa water temperatures to 100 F 38 C c Before entering a spa or hot tub the user should measure the water temperature with an accurate thermometer since...

Page 5: ...ur health Do not permit any electric appliance such as a light telephone radio or television within 5 feet 1 5 m of a spa or hot tub The use of alcohol drugs or medication can greatly increase the ris...

Page 6: ...g death serious injury or property damage Turn off power at the main circuit feeding the AquaLink RS Power Center to disconnect the Power Center from the system Section 3 Installation Figure 1 AquaPal...

Page 7: ...least 8 from any air blowers that may be in the vicinity see Figure 4 3 The Transceiver J box antenna must point towards the sky NOTE To improve performance of the transceiver mount the J box more tha...

Page 8: ...appears see Figure 7 Select a channel 3 UsetheUPandDOWNbuttonstohighlightthe desired RF channel Then press SELECT 4 When the RF channel is selected the following message appears on the AquaPalm displa...

Page 9: ...e the AquaPalm Handheld Remote to turn your pool spa equipment on and off in one of the following ways 1 Activate the main equipment on the front screen by highlighting the selection then press SELECT...

Page 10: ...set temperature When SPA MODE is selected the valve actuators rotate to allow flow to the spa pool spa combination systems and the filter pump is turned on If SPA HEAT is enabled the heater will fire...

Page 11: ...14 Equipment On Off Menu Spa EQUIPMENT FILTER PUMP SPA POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3 MORE 2 POOL OFF OFF OFF OFF 1 select back AIR 78 80 POOL MODE POOL HEATER SPAMODE SPAHEATER MENU...

Page 12: ...re The SPA HEAT enables the heater for the spa The desired temperature can be set from the SET TEMP menu or you can increase decrease the temperature when enabling the heater EQUIPMENT FILTER PUMP SPA...

Page 13: ...Sensor not Installed EQUIPMENT FILTER PUMP SPA POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3 MORE 2 POOL ON OFF OFF OFF 1 select back AIR 78 80 POOL MODE POOL HEATER SPAMODE SPAHEATER MENU EQUIPMENT...

Page 14: ...t to a value greater than 0 and the filter pump is on the system salinity level and output percentage appears on the equipment status screen SET TIME 10 10 05 MON 10 00 AM Use ARROW KEYS to set value...

Page 15: ...N MENU SET TEMP SET TIME PALM OPTIONS 1 2 select back BACKLIGHT LIGHT ON LIGHT OFF Choose setting and press SELECT 1 2 select back AquaPalm AquaPalm AquaPalm To change the Auto Shut off Time Highlight...

Page 16: ...FILTER PUMP SPA POOL HEAT SPA HEAT SOLAR HEAT AUX 1 AUX 2 AUX 3 MORE 1 2 select back 1 2 select back ASSIGN HOTKEYS 1 AUX1 2 AUX2 Choose setting and press SELECT 1 2 select back ASSIGN HOTKEYS 1 AUX3...

Page 17: ...URE SET OUTPUT BOOST START GO BACK EQUIPMENT ON OFF SELECT EQUIPMENT ON OFF ALL OFF LIGHT ON LIGHT OFF 2 MINUTES 5 MINUTES 10 MINUTES 1 2 ONETOUCH MENU SET TEMP POOL HEAT SPA HEAT CHILL MAINTAIN HOURS...

Page 18: ...correctly the system will not communicate AquaPalm Handheld Remote backlight is on and the startup screen is displayed but override switches at the power center do not operate at all 1 Damaged or imp...

Page 19: ...Page 19 NOTES...

Page 20: ...uthorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals such as introducing sanitizing chemicals upstream of...

Reviews: