A ll Button and O neTouch
C ontrol Panels

Summary of Contents for AquaLink RS

Page 1: ...All Button and OneTouch Control Panels...

Page 2: ...if this device is used to control underwater lighting fixtures The conductors on the load side of the ground fault circuit interrupter shall not occupy conduit boxes or enclosures containing other con...

Page 3: ...ring Control panel Wiring Setup for Multiple Controllers DIP Switch Settings OneTouch Control Panel Installation Flush Mount Surface Mount Templates All Button Programming and System Defaults All Butt...

Page 4: ...4 Not Available in CE Models SystemOverview...

Page 5: ...lay 1 To Relay 2 K1 J2 TB 2 JVA Relay Interlock Board JVA Relay Interlock Board is used to tu rn off or on a piece of eq uipm ent as the system sw itches from pool to spa Connect to Plug in JVA Filter...

Page 6: ...hould install an AquaLink RS 2 6 model Controller designed to control separate equipment sets Non Booster Pump Pressure Side The diagram to the right shows standard plumbing for a non booster pump pre...

Page 7: ...Pump Plumbing Solar System Plumbing If a solar system is part of the equipment plumb the solar feed and return lines between the main filter and the heater see diagram to the right Please be sure to...

Page 8: ...ide of the Power Center If you are using the Power Center with built in breaker compartment wire power to the appropriate breakers Pull in appropriate wire for equipment Each piece of equipment requir...

Page 9: ...CenterConnection HighVoltage This diagram shows wiring for a standard relay For light dimming or two speed operation follow wiring instructions included with those relays Power Center Connection High...

Page 10: ...10 Low Voltage Wiring Power Center P C Board If connecting more than 2 items to the RS Power Center red 4 pin terminal bar a multiplex PCB is required PowerCenterConnection LowVoltage...

Page 11: ...e Sensor required Air Sensor must be installed Install sensor outdoors where it will be subjected to shaded air temperature not in sun Connect sensor wires to the 10 pin terminal bar as shown on the w...

Page 12: ...re on the property depending upon convenience and what devices are being controlled AUX B1 through B8 C1 through C8 and D1 through D8 on the indoor control panel operates the relays located in the aux...

Page 13: ...and insert plastic anchors Mount Bracket and secure in place Connect Control Panel Cable to Control Panel Pull Control Panel Cable through the hole in the Mounting Bracket Strip back cable jacket 6 R...

Page 14: ...es starting from the first Control Panel solid line or each may be wired individually from the AquaLink Power Center dotted line or a combination of the two To accomplish the In Series wiring scheme y...

Page 15: ...ding to its installation instructions DIP 3 ON AUX 3 CONTROLS SPA SPILLOVER OPERATES WITH POOL SPA COMBINATION UNITS Turn this switch on and when the AUX 3 button on the AquaLink RS Controller or Spa...

Page 16: ...the box into the wall 6 Depending on what size sheet rock 5 8 or 1 2 determine which side of the cleat to be used a For 1 2 sheet rock face the large side of the cleat towards you see Fig 2 b For 5 8...

Page 17: ...ize is 3 16 Install the sheet rock anchors Drill the 1 hole for the 4 conduc tor wire 3 Pull the 4 conductor wire through the 1 hole in the surface mount box Mount the box to the wall using the screws...

Page 18: ...emplates Drill Thru 3 16 3 Places Drill Thru 1 Figure8 Surface Mount Template Template 2 Surface Mount WARNING Do not cut the sheetrock any bigger than the template Template 1 Flush Mount 4 03 4 03 Fi...

Page 19: ...n Rev G or higher or SPA LINK and press ENTER Follow the prompts to assign each REMOTE button Set Freeze Protection AquaLink RS Freeze Protection senses when the air temperature falls below 38 F and a...

Page 20: ...TIMEOUT Mode The Power Center has complete control for 3 hours After 3 hours the system will return to Auto Mode Programmed On Off times will be overridden during the 3 hours After the three hour tim...

Page 21: ...highlight SYSTEM SETUP press select highlight SPA SWITCH or SPA LINK and press select Highlight the number of remotes you have and press select Use the arrow keys to move the highlight bar to choose w...

Page 22: ...DIAGNOSTICS in the SYSTEM SETUP section of the Menu The DIAGNOSTICS will indicate when the battery needs replacement The battery will keep the clock running during power outages LightDimmer Dimmers c...

Page 23: ...electrical conduit underground from the reducer to the future AquaLink RS Power Center location see page 10 of AquaLink RS Installation Manual for further details on Power Center Use sweep elbows do n...

Page 24: ...rns do not use 90 Elbows so that the SpaLink RS cable can be easily pulled through later Use a snake or similar tool to pull the SpaLink RS cable through the conduit to the Power Center At the Power C...

Page 25: ...cal conduit w sweep elbows for turns 3 1 to 1 Adapter to fit in 1 pipe 1 SpaLink Control O rings For Horizontal Installation into the Deck To house the SpaLink RS plumb a 6 long piece of 1 schedule 40...

Page 26: ...the AquaRite and AquaLink RS Use a Multiplex Kit if more than two items are connected to any 4 pin connector PPD Tool Back View of Bezel Assembly Power Center Printed Circuit Board Back of Power Cente...

Page 27: ...fpowertosystem Disconnectbatteryandturnon power Reconnectbatteryand reset time and date Symptom Problem Possible Solution Power Center override switches operate when in Service or Time Out Mode but th...

Page 28: ...buttons thenturnoffpowertosystem finallyturnoff thenon DIP Switch 1 Turn on power and testsystem Cannot assign Cleaner JVA DIPswitchesnotsetcorrectly DIP Switch 1 must be off and DIP Switch 7 must be...

Page 29: ...eaters except Laars LX 1 Removetheheaterservicedoor 2 Removethefactory installedwirebetweenTerminal1 and Terminal 2 on terminal strip see diagram at right 3 Connect the wires from the AquaLink RS P C...

Page 30: ...low voltage thermostat wires in separate conduit from ANY line voltage wires Failure to do so will cause the thermostat relay to react erratically Guidelines for Hayward Heaters For HM2 Models 150 20...

Page 31: ...elect Device To Be Canceled CANCEL SOME CANCEL ALL FRZPROTECT Press ENTER to Remove All Devices Except Pump from Freeze Protection or Cancel to Abort AUXLABEL Select AUX to Remove Label From DIMMERS P...

Page 32: ...h Light Bedroom Light Bug Light Cabana Light Color Wheel Light Deck Light Dock Light Drive Light East Light Entry Light Equipment Light Fan Light Fence Light Flood Light Fountain Light Front Light Gar...

Page 33: ...ELS OK GO BA CK 1 2 3 SPA SWITCH 1 2 3 SPA LINK PRODU CT IN FO C LEAR MEMORY SYSTEM SETU P ON ETOUC H ON OFF ON ETOUC H 1 ON ETOUC H 2 ON ETOUC H 3 OFF ON PROGRA M Select Equipment A DD PR OGRA M SET...

Page 34: ...R e d B ro w n To R e m o te b row n term b ar To S e ns ors e tc g ree n te rm b a r To C o ntrolle r re d te rm ba r 4 3 2 1 6 5 4 3 2 1 B l u e R e d N o t U s e d B l a c k N o t U s e d R e d B...

Page 35: ...35 Notes...

Page 36: ...07 763 7785 480 S Service Road West Oakville Ontario Canada L6K 2H4 905 844 8233 FAX 905 844 2635 Litho in USA Water Pik Technologies Inc Sheet 6594 Rev E 9 01 For Technical Support call 707 776 8200...