Page 37
6.15.9 To Set the Priming Speed
Whenever the variable speed pump is turned on it will go into the priming mode for a predetermined amount of time
(1-5 minutes). This menu allows for the priming speed to be adjusted.
NOTE
The priming parameters for the IntelliFlo
®
are set at the pump.
In the VSP SETTINGS menu, highlight PRIME and press SELECT. Use the UP/DOWN arrow keys to highlight the
desired pump, then press SELECT. Use the UP/DOWN arrow keys to highlight SET SPEED, then press SELECT.
Use the UP/DOWN arrow keys to set value, then press SELECT.
VSP SETTINGS
PUMP MODEL
PUMP APPLICATION
SCALE/MIN-MAX
SPEED/LABELS
PRIME
Highlight an item
and press SELECT
PRIME SETTINGS
PUMP 1
PUMP 2
PUMP 3
PUMP 4
Highlight an item
and press SELECT
PRIME SETTINGS
PUMP 1
SET SPEED
SET DURATION
Highlight an item
and press SELECT
SET PRIME SPEED
(RPM)
2500
Use ARROW KEYS to set
value. Press SELECT to
continue
6.15.10
To Set the Priming Duration
This menu allows for the user to set the length of time the priming takes place (1-5 minutes).
In the VSP SETTINGS menu, highlight PRIME and press SELECT. Use the UP/DOWN arrow keys to highlight
the desired pump, then press SELECT. Use the UP/DOWN arrow keys to highlight SET DURATION, then press
SELECT. Use the UP/DOWN arrow keys to set value, the press SELECT.
VSP SETTINGS
PUMP MODEL
PUMP APPLICATION
MIN-MAX SETTINGS
SPEED/LABELS
PRIME
Highlight an item
and press SELECT
PRIME SETTINGS
PUMP 1
PUMP 2
PUMP 3
PUMP 4
Highlight an item
and press SELECT
PRIME SETTINGS
PUMP 1
SET SPEED
SET DURATION
Highlight an item
and press SELECT
SET PRIME TIME
(MINUTES)
1
Use ARROW KEYS to set
value. Press SELECT to
continue