background image

LIMITED WARRANTY

Thank you for purchasing Jandy

®

 pool and spa products. Jandy Pool Products, Inc. warrants all parts to be free

from  manufacturing  defects  in  materials  and  workmanship  for  a  period  of  one  year  from  the  date  of  retail 

purchase, with the following exceptions:

• AquaLink

®

 RS units installed with Jandy

®

 Surge Protection Kits will be covered for two years.

• NeverLube

®

 valves are warranted for the life of pool and/or spa on which they were originally installed.

• AquaPure

TM

 Electronic Chlorine Generator Electrolytic Cells carry a 5 year limited warranty on a prorated basis.

This warranty is limited to the first retail purchaser, is not transferable, and does not apply to products that have 

been moved from their original installation sites. The liability of Jandy Pool Products, Inc. shall not exceed the 

repair  or  replacement  of  defective  parts  and  does  not  include  any  costs  for  labor  to  remove  and  reinstall  the 

defective  part,  transportation  to  or  from  the  factory,  and  any  other  materials  required  to  make  the  repair. This 

warranty does not cover failures or malfunctions resulting from the following:
1. Failure to properly install, operate or maintain the product(s) in accordance with our published Installation,

Operation and Maintenance Manuals provided with the product(s).

2. The workmanship of any installer of the product(s).

3. Not maintaining a proper chemical balance in your pool and/or spa [pH level between 7.2 and 7.8, Total

Alkalinity (TA) between 80 to 120 ppm, Total Dissolved Solids (TDS) less than 2000 not including salt ppm].

4. Abuse, alteration, accident, fire, flood, lightning, rodents, insects, negligence or acts of God.

5. Scaling, freezing, or other conditions causing inadequate water circulation.

6. Operating the product(s) at water flow rates outside the published minimum and maximum specifications.

7. Use of non-factory authorized parts or accessories in conjunction with the product(s).

8. Chemical contamination of combustion air or improper use of sanitizing chemicals, such as introducing

sanitizing chemicals upstream of the heater and cleaner hose or through the skimmer.

9. Overheating; incorrect wire runs; improper electrical supply; collateral damage caused by failure of O-Rings,

DE grids, or cartridge elements; or damage caused by running the pump with insufficient quantities of water.

LIMITATION OF LIABILITY:

This is the only warranty given by Jandy Pool Products, Inc. No one is authorized to make any other warranties 

on  behalf  of  Jandy  Pool  Products,  Inc. 

THIS  WARRANTY  IS  IN  LIEU  OF  ALL  OTHER  WARRANTIES, 

EXPRESSED OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF FITNESS 

FOR A  PARTICULAR  PURPOSE AND  MERCHANTABILITY.  JANDY  POOL  PRODUCTS,  INC.  EXPRESSLY 

DISCLAIMS  AND  EXCLUDES  ANY  LIABILITY  FOR  CONSEQUENTIAL,  INCIDENTAL,  INDIRECT  OR 

PUNITIVE DAMAGES FOR BREACH OF ANY EXPRESSED OR IMPLIED WARRANTY.

 This  warranty  gives 

you specific legal rights. You may also have other rights which vary by state or province.

WARRANTY CLAIMS:

For prompt warranty consideration, contact your dealer and provide the following information: proof of purchase, 

model  number,  serial  number  and  date  of  installation.  The  installer  will  contact  the  factory  for  instructions 

regarding the claim and to determine the location of the nearest designated service center. If the dealer is not 

available,  you  can  locate  a  service  center  in  your  area  by  visiting  www.jandy.com  or  by  calling  our  technical 

support  department  at  (707)  776-8200  extension  260.  All  returned  parts  must  have  a  Returned  Material 

Authorization number to be evaluated under the terms of this warranty.

6000 Condor Drive • Moorpark, CA USA 93021  •  707.776.8200  •  Fax 707.763.7785

Litho in U.S.A. © Waterpik Technologies 0401

Jandy Pool Products, Inc.

H0572200A

ETl lISTED

CONFORMS TO

Ul STD 1563

CERTIFIED TO

CAN/CSA C22.2 NO. 218.1

PDA HANDHElD REMOTE  

FCC ID:  S8F826X

PDA TRANSCEIVER  

FCC ID:  S8F8252

Litho in U.S.A. © Jandy Pool Products, Inc. 0507

Summary of Contents for AquaLink R

Page 1: ...s These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not...

Page 2: ......

Page 3: ...4 2 Restarting the System Clear Memory Menu 23 4 3 PDA System Defaults and General Modes 23 4 4 PDA Handheld Remote Menu Flow Chart 25 Section 5 Troubleshooting 26 5 1 PDA Quick Troubleshooting Guide...

Page 4: ...egnant or possibly pregnant women should limit spa water temperatures to 100 F 38 C c Before entering a spa or hot tub the user should measure the water temperature with an accurate thermometer since...

Page 5: ...ur health Do not permit any electric appliance such as a light telephone radio or television within 5 feet 1 5 m of a spa or hot tub The use of alcohol drugs or medication can greatly increase the ris...

Page 6: ...ital Assistant PDA System Sub Assembly Power Centers Sold Separately Standard Power Center with mounting brackets Sub Panel Power Center with mounting brackets and circuit breaker mounting plate Two 2...

Page 7: ...Watts Incandescent Low Voltage Class Two 1 A 24 VAC Service Switch All Circuits located at Power Center in Service Mode Dimensions Standard Power Center 5 14 13 Sub Panel Power Center 20 14 5 Note Br...

Page 8: ...etween pool and spa consult the Jandy Valve Actuator Installation and Operation Manual to ensure that the JVAs are synchronized and rotate properly Please consult the Jandy Valve Plumbing Manual for f...

Page 9: ...ilter Pump Pool Intake Spa Intake Spa Return Pool Return Check Valve Spa Make up Booster Pump 2 3 3 Non Booster Pump Pool Cleaner Plumbing Filter Filter Pump Pool Intake Spa Intake Spa Return Pool Ret...

Page 10: ...Power Center Filter Pump Relay Aux 3 Relay Transformer Earth Ground Black White Primary Low voltage raceway do not run high voltage in this compartment From Main Power Ground White White Black Black F...

Page 11: ...the two 2 line terminals and connect equipment power to the two 2 load terminals on the same relay For each piece of 120 volt equipment connect power to a line terminal and connect equipment to a load...

Page 12: ...lling a 12 volt light a 120 volt 12 volt step down AC transformer listed certified for the application must be used For more information about 12 volt installations refer to the Jandy Digital Color Ch...

Page 13: ...C Power Supply Junction Box Figure 5 120 Volt Jandy Pool and Spa Light Wiring Diagram Figure 6 12 Volt Jandy Pool and Spa Light Wiring Diagram GFCI Ground Ground Neutral Black White Green 12V Jandy Li...

Page 14: ...es are kept from being pinched or damaged CAUTION DO NOT INSTALL BATTERY until ready to power up system 3 3 2 PDA J Box Cable Connection to Power Center PCB Make provision for the cable to be run betw...

Page 15: ...ure switches 4 Turn the heater thermostat s to maximum setting 5 Turn the heater switch to the ON position For dual thermostat heaters turn switch to Spa position Figure 9 Lite2 Heater Connection Powe...

Page 16: ...ction configuration connect the orange black and black orange wires to one contact and the yellow black wire to the other contact see Figure 15 Limit Switch Factory Installed Wire Nut R Limit Switch R...

Page 17: ...solar pump output on the PCB Set the time to 11 59 PM at 12 00 AM the AquaLink RS will auto relabel Solar as Heat Pump Otherwise the AquaLink RS will auto relabel Solar as Heat Pump within 24 hours 5...

Page 18: ...n 10 Pin Terminal Bar 10 9 8 7 6 5 4 3 2 1 Note Do not coil the JVA wires inside Power Center To shorten the wire remove the JVA cover and disconnect the wire Shorten strip and reconnect 3 For alterna...

Page 19: ...ceiver and the PDA Transceiver J box must be set to the same RF channel 1 At the Transceiver J box remove the cover to expose the PCB see Figure 20 Figure 20 PDA Transceiver J Box Internal View 2 On t...

Page 20: ...e LEARN MODE 5 At the PCB in the Transceiver J box slide the Learn Switch to LEARN ON See Figure 22 SET RF CHANNEL RF CHANNEL 1 Use ARROW KEYS to set the RF CHANNEL Press SELECT to continue Pool Digit...

Page 21: ...TUP Pool Digital Assistant 1 2 select back PDA SET TEMP POOL HEAT 80 F SPA HEAT 104 F Highlight an item and press SELECT Pool Digital Assistant 1 2 select back PDA SET TEMP POOL HEAT 80 F SPA HEAT 104...

Page 22: ...ERAL LABELS LIGHT LABELS WTRFALL LABELS CUSTOM LABEL Pool Digital Assistant 1 2 select back PDA LABEL AUX1 GENERAL LABELS AUX1 AERATOR AIR BLOWER BACKWASH BOOSTER PUMP CHEM FEED CLEANER MORE Pool Digi...

Page 23: ...MEMORY ERASING ALL SETTINGS please wait Figure 30 Clear Memory Menu 4 3 PDA System Defaults and General Modes Default Temperature Pool Spa Combination Default Pool Temp 80 F Default Spa Temp 102 F Def...

Page 24: ...ws two 2 options for operating the pool equipment on the first day of operation Option 1 Once all programming of equipment is completed the AquaLink RS PDA will automatically review all programs and t...

Page 25: ...CTION AIR TEMP DEGREES F C ENABLED DISABLED FAHRENHEIT CELCIUS SET TEMP PUMP LOCKOUT ENABLED DISABLED BOOST SET AQUAPURE SET OUTPUT AQUAPURE SET TIME HELP SERVICE DIAGNOSTICS START GO BACK EQUIPMENT O...

Page 26: ...to the transceiver J box Also check the installation of the PPD on the power center PCB If the PPD is not seated correctly the system will not communicate PDA Handheld Remote backlight is on and the...

Page 27: ...ches first turn off all equipment Do not program any auxiliaries until all DIP switches are set Turn off all equipment buttons then turn off power to the system finally turn off then on DIP switch 1 T...

Page 28: ...minal bar To Sensors etc green terminal bar To Controller red terminal bar 4 3 2 1 6 5 4 3 2 1 Blue Red Black Red Black F Pump Aux 2 Aux 3 Aux 6 Aux 5 Aux 4 Relay Sockets 24 VDC output JVA Sockets 24...

Page 29: ...ow speed IMPORTANT You must also install a Jandy Two Speed Relay DIP 3 ON AUX 3 Controls Spa Spillover Operates with Pool Spa Combination Turn this switch ON and when the AUX 3 button on the AquaLink...

Page 30: ...Normal operation Factory adjustment when this switch is on temperature delays are eliminated and solar temperature is displayed Do not leave this switch in the ON position 6 Spare Aux activates with F...

Page 31: ...No change 4 Heater cool down operates Heater cool down disabled 5 Normal operation Factory adjustment when this switch is on temperature delays are eliminated and solar temperature is displayed Do not...

Page 32: ...1 Sprinkler 2 Sprinkler 3 Stereo Stream Swim Jet Timed Aux Valve s Wtr Feature Whirlpool 1 2 3 Back Basement Beach Bedroom Bug Cabana Color Wheel Deck Dock Drive East Entry Equipment Fan Fence Flood F...

Page 33: ...Page 33 NOTES...

Page 34: ...Page 34 NOTES...

Page 35: ......

Page 36: ...or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals such as introducing sanitizing chemicals upstream of the heater and...