2. Procedures

2.1  Opening Pump 

WARNING

Turn off the pump and main breaker in the pump 

electrical circuit before starting the procedure. Failure 

to comply could cause a shock hazard, which could 

result in property damage, severe personal injury, 

and/or death.

WARNING

Due to the potential risk of fire, electric shock, or 

injuries to persons, Jandy

 

Pumps must be installed 

in accordance with the National Electrical Code

®

 

(NEC

®

), all local electrical and safety codes, and the 

Occupational Safety and Health Act (OSHA). Copies 

of the NEC may be ordered from the National Fire 

Protection Association, 470 Atlantic Ave., Boston, 

MA 02210, or obtained from your local government 

inspection agency.

In Canada, Jandy

 

Pumps must be installed in  

accordance with the Canadian Electrical Code 

(CEC).

1.  Turn off the pump. Switch off the circuit breaker 

to the pump motor.

2.  Close all necessary isolation valves to prevent 

pool water from reaching the pump.

3.  Following the markings on the lid’s locking ring, 

turn the ring counter-clockwise until the ‘START’ 

marking aligns with the ports. Carefully remove 

the lid.

4.  Depending on the model of the pump, remove 

either the lid o-ring or the lid seal. 

Section 2.2

 

explains how to determine whether your model 

uses a lid o-ring or a lid seal.

5.  Clean all lid sealing surfaces. Remove debris in 

the lid o-ring groove or lid groove and on the 

sealing surface on the pump housing. Debris on lid 

sealing surfaces can cause air leaks in the system.

    WARNING

Follow all filter manufacturer’s instructions. Never 

attempt to assemble, disassemble or adjust the 

filter when there is pressurized air in the system. 

Starting the pump while there is any pressurized 

air in the system can cause the filter lid to be 

blown off, which can cause death, serious 

personal injury or property damage.

6.  Go to the appropriate section:
 

2.2 Replacing Lid Seal or Lid O-ring  

      (Kit R0449100)

 

2.3 Replacing Pump Debris Trap Basket  

      (Kit R0448900)

If the lid part number is on the top of the lid, 

use a lid seal. 

Top View of Lid

(Newer Model)

Figure 3. Newer Model Lid

b.  If the part number is on top of the lid (see 

Figure 3), the pump is a newer model and uses 

a lid seal. Go to Step 3.

Figure 2. Older Model Lid 

 

2.4 Replacing Lid with Locking Ring and Seal  

      (Kit R0448800)

2.2  Replacing Lid Seal or Lid O-ring 

       (Kit R0449100)

The lid seal is used with newer model pump lids, 

and the lid o-ring is used with older model pump lids. 

NOTE  The lid seal has a three-lobed cross section and 

    the lid o-ring has a round cross section.

1.  Determine whether your pump lid is a newer or 

older model by locating the lid part number.

a.  If the part number is on the bottom of the lid 

(see Figure 2), the pump is an older model and 

uses a lid o-ring. Go to Step 2.

If the lid part number is on a raised ridge 

on the bottom of the lid, use a lid o-ring.

Bottom View of Lid

 (Older Model)

Page 2

 

Jandy

®

 Pro Series PHP(F/M), WFTR, and MHPM Pumps, Lid w/ Locking Ring and Seal, Lid Seal and O-ring, and 

Basket   

|

   Replacement Kit Instructions

Summary of Contents for PlusHP Series

Page 1: ...e lid seal or lid o ring and the pump debris trap basket on Jandy Pro Series PlusHP PHP Models PHPF PHPM Water Features WFTR and MaxHP MHP Model MHPM Pumps These replacement kits are designed to be used with both newer and older model Jandy PHP WFTR and MHP Pumps Refer to Figure 1 and the parts list on this page to identify the parts in each kit These instructions must be followed exactly Read the...

Page 2: ...ousing Debris on lid sealing surfaces can cause air leaks in the system WARNING Follow all filter manufacturer s instructions Never attempt to assemble disassemble or adjust the filter when there is pressurized air in the system Starting the pump while there is any pressurized air in the system can cause the filter lid to be blown off which can cause death serious personal injury or property damag...

Page 3: ...use the filter lid to be blown off which can cause death serious personal injury or property damage 1 Comply with the warnings and follow steps 1 5 in Section 2 1 Opening Pump 2 Lift the pump debris trap basket out of the pump 3 Before installing the new debris trap basket remove all debris from the pump 4 Place the new pump debris trap basket into the pump Make sure that the slot of the basket is...

Page 4: ...manufacturer s instructions on how to bleed all air from the filter WARNING Follow all filter manufacturer s instructions Never attempt to assemble disassemble or adjust the filter when there is pressurized air in the system Starting the pump while there is any pressurized air in the system can cause the filter lid to be blown off which can cause death serious per sonal injury or property damage 4...

Reviews: